config DM_RESET
	bool "Enable reset controllers using Driver Model"
	depends on DM && OF_CONTROL
	help
	  Enable support for the reset controller driver class. Many hardware
	  modules are equipped with a reset signal, typically driven by some
	  reset controller hardware module within the chip. In U-Boot, reset
	  controller drivers allow control over these reset signals. In some
	  cases this API is applicable to chips outside the CPU as well,
	  although driving such reset isgnals using GPIOs may be more
	  appropriate in this case.

config SANDBOX_RESET
	bool "Enable the sandbox reset test driver"
	depends on DM_MAILBOX && SANDBOX
	help
	  Enable support for a test reset controller implementation, which
	  simply accepts requests to reset various HW modules without actually
	  doing anything beyond a little error checking.

config STI_RESET
	bool "Enable the STi reset"
	depends on ARCH_STI
	help
	  Support for reset controllers on STMicroelectronics STiH407 family SoCs.
	  Say Y if you want to control reset signals provided by system config
	  block.

config STM32_RESET
	bool "Enable the STM32 reset"
	depends on STM32 || ARCH_STM32MP
	help
	  Support for reset controllers on STMicroelectronics STM32 family SoCs.
	  This resset driver is compatible with STM32 F4/F7 and H7 SoCs.

config TEGRA_CAR_RESET
	bool "Enable Tegra CAR-based reset driver"
	depends on TEGRA_CAR
	help
	  Enable support for manipulating Tegra's on-SoC reset signals via
	  direct register access to the Tegra CAR (Clock And Reset controller).

config TEGRA186_RESET
	bool "Enable Tegra186 BPMP-based reset driver"
	depends on TEGRA186_BPMP
	help
	  Enable support for manipulating Tegra's on-SoC reset signals via IPC
	  requests to the BPMP (Boot and Power Management Processor).

config RESET_BCM6345
	bool "Reset controller driver for BCM6345"
	depends on DM_RESET && ARCH_BMIPS
	help
	  Support reset controller on BCM6345.

config RESET_UNIPHIER
	bool "Reset controller driver for UniPhier SoCs"
	depends on ARCH_UNIPHIER
	default y
	help
	  Support for reset controllers on UniPhier SoCs.
	  Say Y if you want to control reset signals provided by System Control
	  block, Media I/O block, Peripheral Block.

config AST2500_RESET
	bool "Reset controller driver for AST2500 SoCs"
	depends on DM_RESET && WDT_ASPEED
	default y if ASPEED_AST2500
	help
	  Support for reset controller on AST2500 SoC. This controller uses
	  watchdog to reset different peripherals and thus only supports
	  resets that are supported by watchdog. The main limitation though
	  is that some reset signals, like I2C or MISC reset multiple devices.

config RESET_ROCKCHIP
	bool "Reset controller driver for Rockchip SoCs"
	depends on DM_RESET && ARCH_ROCKCHIP && CLK
	default y
	help
	  Support for reset controller on rockchip SoC. The main limitation
	  though is that some reset signals, like I2C or MISC reset multiple
	  devices.

config RESET_MESON
	bool "Reset controller driver for Amlogic Meson SoCs"
	depends on DM_RESET && ARCH_MESON
	imply REGMAP
	default y
	help
	  Support for reset controller on Amlogic Meson SoC.