summaryrefslogtreecommitdiff
path: root/Documentation/ABI
diff options
context:
space:
mode:
authorHarald Geyer <harald@ccbib.org>2013-12-01 15:08:00 +0000
committerJonathan Cameron <jic23@kernel.org>2013-12-03 20:22:29 +0000
commitac216aa290c48a5e9d7b9f2473abb977a175683a (patch)
tree9292b2f5794f8620eb19cc6c0f6f34be04b77fd5 /Documentation/ABI
parent6f93910ebae3f0ca4c0db1ba098d1635618b9c2f (diff)
downloadlinux-stable-ac216aa290c48a5e9d7b9f2473abb977a175683a.tar.gz
linux-stable-ac216aa290c48a5e9d7b9f2473abb977a175683a.tar.bz2
linux-stable-ac216aa290c48a5e9d7b9f2473abb977a175683a.zip
iio: Add support for humidity sensors
There are already humidity sensors in the hwmon subsystem, so we use their unit (milli percent) here as well. Signed-off-by: Harald Geyer <harald@ccbib.org> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Diffstat (limited to 'Documentation/ABI')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio13
1 files changed, 13 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index b20e829d350f..6e02c5029152 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -197,6 +197,19 @@ Description:
Raw pressure measurement from channel Y. Units after
application of scale and offset are kilopascal.
+What: /sys/bus/iio/devices/iio:deviceX/in_humidityrelative_raw
+KernelVersion: 3.14
+Contact: linux-iio@vger.kernel.org
+Description:
+ Raw humidity measurement of air. Units after application of
+ scale and offset are milli percent.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_humidityrelative_input
+KernelVersion: 3.14
+Contact: linux-iio@vger.kernel.org
+Description:
+ Scaled humidity measurement in milli percent.
+
What: /sys/bus/iio/devices/iio:deviceX/in_accel_offset
What: /sys/bus/iio/devices/iio:deviceX/in_accel_x_offset
What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_offset