summaryrefslogtreecommitdiff
path: root/drivers
diff options
context:
space:
mode:
authorNeilBrown <neilb@suse.de>2012-07-03 15:55:33 +1000
committerNeilBrown <neilb@suse.de>2012-07-03 15:55:33 +1000
commit055d3747dbf00ce85c6872ecca4d466638e80c22 (patch)
treee58062bddc9b1770328c450c780d60e72459173e /drivers
parent5f066c632fcfd2a33f2eb7077c15c630e9f5ea5b (diff)
downloadlinux-3.10-055d3747dbf00ce85c6872ecca4d466638e80c22.tar.gz
linux-3.10-055d3747dbf00ce85c6872ecca4d466638e80c22.tar.bz2
linux-3.10-055d3747dbf00ce85c6872ecca4d466638e80c22.zip
md/raid10: fix failure when trying to repair a read error.
commit 58c54fcca3bac5bf9290cfed31c76e4c4bfbabaf md/raid10: handle further errors during fix_read_error better. in 3.1 added "r10_sync_page_io" which takes an IO size in sectors. But we were passing the IO size in bytes!!! This resulting in bio_add_page failing, and empty request being sent down, and a consequent BUG_ON in scsi_lib. [fix missing space in error message at same time] This fix is suitable for 3.1.y and later. Cc: stable@vger.kernel.org Reported-by: Christian Balzer <chibi@gol.com> Signed-off-by: NeilBrown <neilb@suse.de>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/md/raid10.c6
1 files changed, 3 insertions, 3 deletions
diff --git a/drivers/md/raid10.c b/drivers/md/raid10.c
index bcf6ea8acc9..ae73e29298b 100644
--- a/drivers/md/raid10.c
+++ b/drivers/md/raid10.c
@@ -2310,7 +2310,7 @@ static void fix_read_error(struct r10conf *conf, struct mddev *mddev, struct r10
if (r10_sync_page_io(rdev,
r10_bio->devs[sl].addr +
sect,
- s<<9, conf->tmppage, WRITE)
+ s, conf->tmppage, WRITE)
== 0) {
/* Well, this device is dead */
printk(KERN_NOTICE
@@ -2349,7 +2349,7 @@ static void fix_read_error(struct r10conf *conf, struct mddev *mddev, struct r10
switch (r10_sync_page_io(rdev,
r10_bio->devs[sl].addr +
sect,
- s<<9, conf->tmppage,
+ s, conf->tmppage,
READ)) {
case 0:
/* Well, this device is dead */
@@ -2512,7 +2512,7 @@ read_more:
slot = r10_bio->read_slot;
printk_ratelimited(
KERN_ERR
- "md/raid10:%s: %s: redirecting"
+ "md/raid10:%s: %s: redirecting "
"sector %llu to another mirror\n",
mdname(mddev),
bdevname(rdev->bdev, b),