block: implement request_queue->dma_drain_needed
Draining shouldn't be done for commands where overflow may indicate
data integrity issues. Add dma_drain_needed callback to
request_queue. Drain buffer is appened iff this function returns
non-zero.
Signed-off-by: Tejun Heo <htejun@gmail.com>
Cc: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
Diffstat (limited to 'block')
-rw-r--r-- | block/blk-merge.c | 2 | ||||
-rw-r--r-- | block/blk-settings.c | 7 |
2 files changed, 6 insertions, 3 deletions
diff --git a/block/blk-merge.c b/block/blk-merge.c index 39f2e077a014..bef1b4d0fc02 100644 --- a/block/blk-merge.c +++ b/block/blk-merge.c @@ -220,7 +220,7 @@ new_segment: bvprv = bvec; } /* segments in rq */ - if (q->dma_drain_size) { + if (q->dma_drain_size && q->dma_drain_needed(rq)) { sg->page_link &= ~0x02; sg = sg_next(sg); sg_set_page(sg, virt_to_page(q->dma_drain_buffer), diff --git a/block/blk-settings.c b/block/blk-settings.c index 13536a388d27..9a8ffdd0ce3d 100644 --- a/block/blk-settings.c +++ b/block/blk-settings.c @@ -296,6 +296,7 @@ EXPORT_SYMBOL(blk_queue_stack_limits); * blk_queue_dma_drain - Set up a drain buffer for excess dma. * * @q: the request queue for the device + * @dma_drain_needed: fn which returns non-zero if drain is necessary * @buf: physically contiguous buffer * @size: size of the buffer in bytes * @@ -315,14 +316,16 @@ EXPORT_SYMBOL(blk_queue_stack_limits); * device can support otherwise there won't be room for the drain * buffer. */ -int blk_queue_dma_drain(struct request_queue *q, void *buf, - unsigned int size) +extern int blk_queue_dma_drain(struct request_queue *q, + dma_drain_needed_fn *dma_drain_needed, + void *buf, unsigned int size) { if (q->max_hw_segments < 2 || q->max_phys_segments < 2) return -EINVAL; /* make room for appending the drain */ --q->max_hw_segments; --q->max_phys_segments; + q->dma_drain_needed = dma_drain_needed; q->dma_drain_buffer = buf; q->dma_drain_size = size; |