summaryrefslogtreecommitdiff
path: root/src/mscorlib/src/System/Diagnostics/log.cs
diff options
context:
space:
mode:
Diffstat (limited to 'src/mscorlib/src/System/Diagnostics/log.cs')
-rw-r--r--src/mscorlib/src/System/Diagnostics/log.cs128
1 files changed, 0 insertions, 128 deletions
diff --git a/src/mscorlib/src/System/Diagnostics/log.cs b/src/mscorlib/src/System/Diagnostics/log.cs
deleted file mode 100644
index f38eaccabc..0000000000
--- a/src/mscorlib/src/System/Diagnostics/log.cs
+++ /dev/null
@@ -1,128 +0,0 @@
-// Licensed to the .NET Foundation under one or more agreements.
-// The .NET Foundation licenses this file to you under the MIT license.
-// See the LICENSE file in the project root for more information.
-
-namespace System.Diagnostics
-{
- using System;
- using System.IO;
- using System.Collections;
- using System.Runtime.CompilerServices;
- using Encoding = System.Text.Encoding;
- using System.Runtime.Versioning;
- using System.Diagnostics.CodeAnalysis;
-
- using Console = Internal.Console;
-
- // LogSwitchLevelHandlers are triggered when the level of a LogSwitch is modified
- // NOTE: These are NOT triggered when the log switch setting is changed from the
- // attached debugger.
- //
- internal delegate void LogSwitchLevelHandler(LogSwitch ls, LoggingLevels newLevel);
-
-
- internal static class Log
- {
- // Switches allow relatively fine level control of which messages are
- // actually shown. Normally most debugging messages are not shown - the
- // user will typically enable those which are relevant to what is being
- // investigated.
- //
- // An attached debugger can enable or disable which messages will
- // actually be reported to the user through the COM+ debugger
- // services API. This info is communicated to the runtime so only
- // desired events are actually reported to the debugger.
- internal static Hashtable m_Hashtable;
- private static volatile bool m_fConsoleDeviceEnabled;
- private static volatile LogSwitchLevelHandler _LogSwitchLevelHandler;
- private static Object locker;
-
- // Constant representing the global switch
- public static readonly LogSwitch GlobalSwitch;
-
-
- static Log()
- {
- m_Hashtable = new Hashtable();
- m_fConsoleDeviceEnabled = false;
- //pConsole = null;
- //iNumOfMsgHandlers = 0;
- //iMsgHandlerArraySize = 0;
- locker = new Object();
-
- // allocate the GlobalSwitch object
- GlobalSwitch = new LogSwitch("Global", "Global Switch for this log");
-
- GlobalSwitch.MinimumLevel = LoggingLevels.ErrorLevel;
- }
-
- internal static void InvokeLogSwitchLevelHandlers(LogSwitch ls, LoggingLevels newLevel)
- {
- LogSwitchLevelHandler handler = _LogSwitchLevelHandler;
- if (handler != null)
- handler(ls, newLevel);
- }
-
-
- // Property to Enable/Disable ConsoleDevice. Enabling the console device
- // adds the console device as a log output, causing any
- // log messages which make it through filters to be written to the
- // application console. The console device is enabled by default if the
- // ??? registry entry or ??? environment variable is set.
- public static bool IsConsoleEnabled
- {
- get { return m_fConsoleDeviceEnabled; }
- set { m_fConsoleDeviceEnabled = value; }
- }
-
- // Generates a log message. If its switch (or a parent switch) allows the
- // level for the message, it is "broadcast" to all of the log
- // devices.
- //
- public static void LogMessage(LoggingLevels level, LogSwitch logswitch, String message)
- {
- if (logswitch == null)
- throw new ArgumentNullException("LogSwitch");
-
- if (level < 0)
- throw new ArgumentOutOfRangeException(nameof(level), SR.ArgumentOutOfRange_NeedNonNegNum);
-
- // Is logging for this level for this switch enabled?
- if (logswitch.CheckLevel(level) == true)
- {
- // Send message for logging
-
- // first send it to the debugger
- Debugger.Log((int)level, logswitch.strName, message);
-
- // Send to the console device
- if (m_fConsoleDeviceEnabled)
- {
- Console.Write(message);
- }
- }
- }
-
- /*
- * Following are convenience entry points; all go through Log()
- * Note that the (Switch switch, String message) variations
- * are preferred.
- */
- public static void Trace(LogSwitch logswitch, String message)
- {
- LogMessage(LoggingLevels.TraceLevel0, logswitch, message);
- }
-
- public static void Trace(String message)
- {
- LogMessage(LoggingLevels.TraceLevel0, GlobalSwitch, message);
- }
-
-
- // Native method to inform the EE about the creation of a new LogSwitch
- [MethodImplAttribute(MethodImplOptions.InternalCall)]
- internal static extern void AddLogSwitch(LogSwitch logSwitch);
- [MethodImplAttribute(MethodImplOptions.InternalCall)]
- internal static extern void ModifyLogSwitch(int iNewLevel, String strSwitchName, String strParentName);
- }
-}