summaryrefslogtreecommitdiff
path: root/doc/mgmt-api.txt
blob: b4ddf77068b4dfff544d779556fb606bb60e21b4 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
Bluetooth Management API
*************************

Copyright (C) 2008-2009  Marcel Holtmann <marcel@holtmann.org>


Overview
========

This document describes the format of data used for communicating with
the kernel using a so-called Bluetooth Management sockets. These sockets
are available starting with Linux kernel version 3.4

The following kernel versions introduced new commands, new events or
important fixes to the Bluetooth Management API:

Linux kernel v3.4	Version 1.0
Linux kernel v3.5	Version 1.1
Linux kernel v3.7	Version 1.2
Linux kernel v3.9	Version 1.3
Linux kernel v3.13	Version 1.4
Linux kernel v3.15	Version 1.5
Linux kernel v3.16	Version 1.6
Linux kernel v3.17	Version 1.7
Linux kernel v3.19	Version 1.8
Linux kernel v4.1	Version 1.9 (not yet released)

Version 1.1 introduces Set Device ID command.

Version 1.2 introduces Passkey Notify event.

Version 1.3 does not introduce any new command or event.

Version 1.4 introduces Set Advertising, Set BR/EDR, Set Static Address
and Set Scan Parameters commands. The existing Set Discoverable command
gained an extra setting for limited discoverable mode. The device name
is now provided in the scan response data for Low Energy.

Version 1.5 introduces Set Secure Connections, Set Debug Keys, Set Privacy
and Load Identity Resolving Keys commands. It also introduces New Identity
Resolving Key and New Signature Resolving Key events.

Version 1.6 introduces Get Connection Information command. It also updates
the Device Found event to combine advertising data and scan response data
into a single event.

Version 1.7 introduces Get Clock Information, Add Device, Remove Device,
Load Connection Parameters, Read Unconfigured Index List, Read Controller
Configuration Information, Set External Configuration and Set Public Address
commands. It also introduces Device Added, Device Removed, New Connection
Parameter, Unconfigured Index Added, Unconfigured Index Removed and New
Configuration Options events. The existing Set Debug Keys command gained
an extra setting for enabling SSP debug mode.

Version 1.8 introduces Start Service Discovery command. It also adds new
Long Term Key types for LE Secure Connection feature.

Version 1.9 introduces a new static address setting and allows the usage
of Set Fast Connectable when controller is powered off. The existing Set
Advertising command gained an extra setting for enabling undirected
connectable advertising.


Example
=======

The Bluetooth management sockets can be created by setting the hci_channel
member of struct sockaddr_hci to HCI_CHANNEL_CONTROL (3) when creating a
raw HCI socket. In C the needed code would look something like the following:

int mgmt_create(void)
{
	struct sockaddr_hci addr;
	int fd;

	fd = socket(PF_BLUETOOTH, SOCK_RAW | SOCK_CLOEXEC | SOCK_NONBLOCK,
                                                                BTPROTO_HCI);
	if (fd < 0)
		return -errno;

	memset(&addr, 0, sizeof(addr));
	addr.hci_family = AF_BLUETOOTH;
	addr.hci_dev = HCI_DEV_NONE;
	addr.hci_channel = HCI_CHANNEL_CONTROL;

	if (bind(fd, (struct sockaddr *) &addr, sizeof(addr)) < 0) {
		int err = -errno;
		close(fd);
		return err;
	}

	return fd;
}

The process creating the mgmt socket is required to have the
CAP_NET_ADMIN capability (e.g. root would have this).


Packet Structures
=================

	Commands:

	0    4    8   12   16   22   24   28   31   35   39   43   47
	+-------------------+-------------------+-------------------+
	|  Command Code     |  Controller Index |  Parameter Length |
	+-------------------+-------------------+-------------------+
	|                                                           |

	Events:

	0    4    8   12   16   22   24   28   31   35   39   43   47
	+-------------------+-------------------+-------------------+
	|  Event Code       |  Controller Index |  Parameter Length |
	+-------------------+-------------------+-------------------+
	|                                                           |

All fields are in little-endian byte order (least significant byte first).

Controller Index can have a special value <non-controller> to indicate that
command or event is not related to any controller. Possible values:

	<controller id>		0x0000 to 0xFFFE
	<non-controller>	0xFFFF


Error Codes
===========

The following values have been defined for use with the Command Status
and Command Complete events:

0x00	Success
0x01	Unknown Command
0x02	Not Connected
0x03	Failed
0x04	Connect Failed
0x05	Authentication Failed
0x06	Not Paired
0x07	No Resources
0x08	Timeout
0x09	Already Connected
0x0A	Busy
0x0B	Rejected
0x0C	Not Supported
0x0D	Invalid Parameters
0x0E	Disconnected
0x0F	Not Powered
0x10	Cancelled
0x11	Invalid Index
0x12	RFKilled
0x13	Already Paired
0x14	Permission Denied

As a general rule all commands generate the events as specified below,
however invalid lengths or unknown commands will always generate a
Command Status response (with Unknown Command or Invalid Parameters
status). Sending a command with an invalid Controller Index value will
also always generate a Command Status event with the Invalid Index
status code.


Read Management Version Information Command
===========================================

	Command Code:		0x0001
	Controller Index:	<non-controller>
	Command Parameters:
	Return Parameters:	Version (1 Octets)
				Revision (2 Octets)

	This command returns the Management version and revision.
	Besides, being informational the information can be used to
	determine whether certain behavior has changed or bugs fixed
	when interacting with the kernel.

	This command generates a Command Complete event on success or
	a Command Status event on failure.


Read Management Supported Commands Command
==========================================

	Command Code:		0x0002
	Controller Index:	<non-controller>
	Command Parameters:
	Return Parameters:	Num_Of_Commands (2 Octets)
				Num_Of_Events (2 Octets)
				Command1 (2 Octets)
				Command2 (2 Octets)
				...
				Event1 (2 Octets)
				Event2 (2 Octets)
				...

	This command returns the list of supported Management commands
	and events.

	The commands Read Management Version Information and Read
	management Supported Commands are not included in this list.
	Both commands are always supported and mandatory.

	The events Command Status and Command Complete are not included
	in this list. Both are implicit and mandatory.

	This command generates a Command Complete event on success or
	a Command Status event on failure.


Read Controller Index List Command
==================================

	Command Code:		0x0003
	Controller Index:	<non-controller>
	Command Parameters:
	Return Parameters:	Num_Controllers (2 Octets)
				Controller_Index[i] (2 Octets)

	This command returns the list of currently known controllers.
	Controllers added or removed after calling this command can be
	monitored using the Index Added and Index Removed events.

	This command generates a Command Complete event on success or
	a Command Status event on failure.


Read Controller Information Command
===================================

	Command Code:		0x0004
	Controller Index:	<controller id>
	Command Parameters:
	Return Parameters:	Address (6 Octets)
				Bluetooth_Version (1 Octet)
				Manufacturer (2 Octets)
				Supported_Settings (4 Octets)
				Current_Settings (4 Octets)
				Class_Of_Device (3 Octets)
				Name (249 Octets)
				Short_Name (11 Octets)

	This command is used to retreive the current state and basic
	information of a controller. It is typically used right after
	getting the response to the Read Controller Index List command
	or an Index Added event.

	The Address parameter describes the controllers public address
	and it can be expected that it is set. However in case of single
	mode Low Energy only controllers it can be 00:00:00:00:00:00. To
	power on the controller in this case, it is required to configure
	a static address using Set Static Address command first.

	If the public address is set, then it will be used as identity
	address for the controller. If no public address is available,
	then the configured static address will be used as identity
	address.

	In the case of a dual-mode controller with public address that
	is configured as Low Energy only device (BR/EDR switched off),
	the static address is used when set and public address otherwise.

	If no short name is set the Short_Name parameter will be empty
	(begin with a nul byte).

	Current_Settings and Supported_Settings is a bitmask with
	currently the following available bits:

		0	Powered
		1	Connectable
		2	Fast Connectable
		3	Discoverable
		4	Bondable
		5	Link Level Security (Sec. mode 3)
		6	Secure Simple Pairing
		7	Basic Rate/Enhanced Data Rate
		8	High Speed
		9	Low Energy
		10	Advertising
		11	Secure Connections
		12	Debug Keys
		13	Privacy
		14	Controller Configuration
		15	Static Address

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Set Powered Command
===================

	Command Code:		0x0005
	Controller Index:	<controller id>
	Command Parameters:	Powered (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to power on or off a controller. The
	allowed Powered command parameter values are 0x00 and 0x01. All
	other values will return Invalid Parameters.

	If discoverable setting is activated with a timeout, then
	switching the controller off will expire this timeout and
	disable discoverable.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Invalid Parameters
				Invalid Index


Set Discoverable Command
========================

	Command Code:		0x0006
	Controller Index:	<controller id>
	Command Parameters:	Discoverable (1 Octet)
				Timeout (2 Octets)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to set the discoverable property of a
	controller. The allowed Discoverable command parameter values
	are 0x00, 0x01 and 0x02. All other values will return Invalid
	Parameters.

	Timeout is the time in seconds and is only meaningful when
	Discoverable is set to 0x01 or 0x02. Providing a timeout
	with 0x00 return Invalid Parameters. For 0x02, the timeout
	value is required.

	The value 0x00 disables discoverable, the value 0x01 enables
	general discoverable and the value 0x02 enables limited
	discoverable.

	This command is only available for BR/EDR capable controllers
	(e.g. not for single-mode LE ones). It will return Not Supported
	otherwise.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	However using a timeout when the controller is not powered will
	return Not Powered error.

	When switching discoverable on and the connectable setting is
	off it will return Rejected error.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Rejected
				Not Supported
				Invalid Parameters
				Not Powered
				Invalid Index


Set Connectable Command
=======================

	Command Code:		0x0007
	Controller Index:	<controller id>
	Command Parameters:	Connectable (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to set the connectable property of a
	controller. The allowed Connectable command parameter values are
	0x00 and 0x01. All other values will return Invalid Parameters.

	This command is available for BR/EDR, LE-only and also dual
	mode controllers. For BR/EDR is changes the page scan setting
	and for LE controllers it changes the advertising type. For
	dual mode controllers it affects both settings.

	For LE capable controllers the connectable setting takes affect
	when advertising is enabled (peripheral) or when directed
	advertising events are received (central).

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	When switching connectable off, it will also switch off the
	discoverable setting. Switching connectable back on will not
	restore a previous discoverable. It will stay off and needs
	to be manually switched back on.

	When switching connectable off, it will expire a discoverable
	setting with a timeout.

	This setting does not affect known devices from Add Device
	command. These devices are always allowed to connect.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Set Fast Connectable Command
============================

	Command Code:		0x0008
	Controller Index:	<controller id>
	Command Parameters:	Enable (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to set the controller into a connectable
	state where the page scan parameters have been set in a way to
	favor faster connect times with the expense of higher power
	consumption.

	The allowed values of the Enable command parameter are 0x00 and
	0x01. All other values will return Invalid Parameters.

	This command is only available for BR/EDR capable controllers
	(e.g. not for single-mode LE ones). It will return Not Supported
	otherwise.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	The setting will be remembered during power down/up toggles.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Failed
				Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Set Bondable Command
====================

	Command Code:		0x0009
	Controller Index:	<controller id>
	Command Parameters:	Bondable (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to set the bondable property of an
	controller. The allowed values for the Bondable command
	parameter are 0x00 and 0x01. All other values will return
	Invalid Parameters.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	Turning bondable on will not automatically switch the controller
	into connectable mode. That needs to be done separately.

	The setting will be remembered during power down/up toggles.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Set Link Security Command
=========================

	Command Code:		0x000A
	Controller Index:	<controller id>
	Command Parameters:	Link_Security (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to either enable or disable link level
	security for an controller (also known as Security Mode 3). The
	allowed values for the Link_Security command parameter are 0x00
	and 0x01. All other values will return Invalid Parameters.

	This command is only available for BR/EDR capable controllers
	(e.g. not for single-mode LE ones). It will return Not Supported
	otherwise.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Set Secure Simple Pairing Command
=================================

	Command Code:		0x000B
	Controller Index:	<controller id>
	Command Parameters:	Secure_Simple_Pairing (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to enable/disable Secure Simple Pairing
	support for a controller. The allowed values for the
	Secure_Simple_Pairing command parameter are 0x00 and 0x01. All
	other values will return Invalid Parameters.

	This command is only available for BR/EDR capable controllers
	supporting the core specification version 2.1 or greater
	(e.g. not for single-mode LE controllers or pre-2.1 ones).

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	In case the controller does not support Secure Simple Pairing,
	the command will fail regardless with Not Supported error.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index

Set High Speed Command
======================

	Command Code:		0x000C
	Controller Index:	<controller id>
	Command Parameters:	High_Speed (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to enable/disable Bluetooth High Speed
	support for a controller. The allowed values for the High_Speed
	command parameter are 0x00 and 0x01. All other values will
	return Invalid Parameters.

	This command is only available for BR/EDR capable controllers
	(e.g. not for single-mode LE ones).

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	To enable High Speed support, it is required that Secure Simple
	Pairing support is enabled first. High Speed support is not
	possible for connections without Secure Simple Pairing.

	When switching Secure Simple Pairing off, the support for High
	Speed will be switched off as well. Switching Secure Simple
	Pairing back on, will not re-enable High Speed support. That
	needs to be done manually.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Not Supported
				Invalid Parameters
				Invalid Index


Set Low Energy Command
======================

	Command Code:		0x000D
	Controller Index:	<controller id>
	Command Parameters:	Low_Energy (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to enable/disable Low Energy support for a
	controller. The allowed values of the Low_Energy command
	parameter are 0x00 and 0x01. All other values will return
	Invalid Parameters.

	This command is only available for LE capable controllers and
	will yield in a Not Supported error otherwise.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	In case the kernel subsystem does not support Low Energy or the
	controller does not either, the command will fail regardless.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Set Device Class
================

	Command Code:		0x000E
	Controller Index:	<controller id>
	Command Parameters:	Major_Class (1 Octet)
				Minor_Class (1 Octet)
	Return Parameters:	Class_Of_Device (3 Octets)

	This command is used to set the major and minor device class for
	BR/EDR capable controllers.

	This command will also implicitly disable caching of pending CoD
	and EIR updates.

	This command is only available for BR/EDR capable controllers
	(e.g. not for single-mode LE ones).

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	In case the controller is powered off, 0x000000 will be returned
	for the class of device parameter. And after power on the new
	value will be announced via class of device changed event.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Set Local Name Command
======================

	Command Code:		0x000F
	Controller Index:	<controller id>
	Command Parameters:	Name (249 Octets)
				Short_Name (11 Octets)
	Return Parameters:	Name (249 Octets)
				Short_Name (11 Octets)

	This command is used to set the local name of a controller. The
	command parameters also include a short name which will be used
	in case the full name doesn't fit within EIR/AD data.

	The name parameters need to always end with a null byte (failure
	to do so will cause the command to fail).

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	The values of name and short name will be remembered when
	switching the controller off and back on again. So the name
	and short name only have to be set once when a new controller
	is found and will stay until removed.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Add UUID Command
================

	Command Code:		0x0010
	Controller Index:	<controller id>
	Command Parameters:	UUID (16 Octets)
				SVC_Hint (1 Octet)
	Return Parameters:	Class_Of_Device (3 Octets)

	This command is used to add a UUID to be published in EIR data.
	The accompanied SVC_Hint parameter is used to tell the kernel
	whether the service class bits of the Class of Device value need
	modifying due to this UUID.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	In case the controller is powered off, 0x000000 will be returned
	for the class of device parameter. And after power on the new
	value will be announced via class of device changed event.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Invalid Parameters
				Invalid Index


Remove UUID Command
===================

	Command Code:		0x0011
	Controller Index:	<controller id>
	Command Parameters:	UUID (16 Octets)
	Return Parameters:	Class_Of_Device (3 Octets)

	This command is used to remove a UUID previously added using the
	Add UUID command.

	When the UUID parameter is an empty UUID (16 x 0x00), then all
	previously loaded UUIDs will be removed.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	In case the controller is powered off, 0x000000 will be returned
	for the class of device parameter. And after power on the new
	value will be announced via class of device changed event.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Invalid Parameters
				Invalid Index


Load Link Keys Command
======================

	Command Code:		0x0012
	Controller Index:	<controller id>
	Command Parameters:	Debug_Keys (1 Octet)
				Key_Count (2 Octets)
				Key1 {
					Address (6 Octets)
					Address_Type (1 Octet)
					Key_Type (1 Octet)
					Value (16 Octets)
					PIN_Length (1 Octet)
				}
				Key2 { }
				...
	Return Parameters:

	This command is used to feed the kernel with currently known
	link keys. The command does not need to be called again upon the
	receiption of New Link Key events since the kernel updates its
	list automatically.

	The Debug_Keys parameter is used to tell the kernel whether to
	accept the usage of debug keys or not. The allowed values for
	this parameter are 0x00 and 0x01. All other values will return
	an Invalid Parameters response.

	Usage of the Debug_Keys parameter is deprecated and has been
	replaced with the Set Debug Keys command. When setting the
	Debug_Keys option via Load Link Keys command it has the same
	affect as setting it via Set Debug Keys and applies to all
	keys in the system.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	Reserved (not in use)
		2	Reserved (not in use)

	Public and random LE addresses are not valid and will be rejected.

	Currently defined Key_Type values are:

		0x00	Combination key
		0x01	Local Unit key
		0x02	Remote Unit key
		0x03	Debug Combination key
		0x04	Unauthenticated Combination key from P-192
		0x05	Authenticated Combination key from P-192
		0x06	Changed Combination key
		0x07	Unauthenticated Combination key from P-256
		0x08	Authenticated Combination key from P-256

	This command can be used when the controller is not powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Load Long Term Keys Command
===========================

	Command Code:		0x0013
	Controller Index:	<controller id>
	Command Parameters:	Key_Count (2 Octets)
				Key1 {
					Address (6 Octets)
					Address_Type (1 Octet)
					Key_Type (1 Octet)
					Master (1 Octet)
					Encryption_Size (1 Octet)
					Encryption_Diversifier (2 Octets)
					Random_Number (8 Octets)
					Value (16 Octets)
				}
				Key2 {  }
				...
	Return Parameters:

	This command is used to feed the kernel with currently known
	(SMP) Long Term Keys. The command does not need to be called
	again upon the receiption of New Long Term Key events since the
	kernel updates its list automatically.

	Possible values for the Address_Type parameter:
		0	Reserved (not in use)
		1	LE Public
		2	LE Random

	The provided Address and Address_Type are the identity of
	a device. So either its public address or static random address.

	Unresolvable random addresses and resolvable random addresses are
	not valid and will be rejected.

	Currently defined Key_Type values are:

		0x00	Unauthenticated key
		0x01	Authenticated key

	This command can be used when the controller is not powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Disconnect Command
==================

	Command Code:		0x0014
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to force the disconnection of a currently
	connected device.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Connected
				Busy
				Invalid Parameters
				Not Powered
				Invalid Index


Get Connections Command
=======================

	Command Code:		0x0015
	Controller Index:	<controller id>
	Command Parameters:
	Return Parameters:	Connection_Count (2 Octets)
				Address1 {
					Address (6 Octets)
					Address_Type (1 Octet)
				}
				Address2 { }
				...

	This command is used to retreive a list of currently connected
	devices.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	For devices using resolvable random addresses with a known
	identity resolving key, the Address and Address_Type will
	contain the identity information.

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Not Powered
				Invalid Index


PIN Code Reply Command
=======================

	Command Code:		0x0016
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				PIN_Length (1 Octet)
				PIN_Code (16 Octets)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to respond to a PIN Code request event.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Connected
				Invalid Parameters
				Not Powered
				Invalid Index


PIN Code Negative Reply Command
===============================

	Command Code:		0x0017
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to return a negative response to a PIN Code
	Request event.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Connected
				Invalid Parameters
				Not Powered
				Invalid Index


Set IO Capability Command
=========================

	Command Code:		0x0018
	Controller Index:	<controller id>
	Command Parameters:	IO_Capability (1 Octet)
	Return Parameters:

	This command is used to set the IO Capability used for pairing.
	The command accepts both SSP and SMP values.

	Possible values for the IO_Capability parameter:
		0	DisplayOnly
		1	DisplayYesNo
		2	KeyboardOnly
		3	NoInputNoOutput
		4	KeyboardDisplay

	Passing a value 4 (KeyboardDisplay) will cause the kernel to
	convert it to 1 (DisplayYesNo) in the case of a BR/EDR
	connection (as KeyboardDisplay is specific to SMP).

	This command can be used when the controller is not powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Pair Device Command
===================

	Command Code:		0x0019
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				IO_Capability (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to trigger pairing with a remote device.
	The IO_Capability command parameter is used to temporarily (for
	this pairing event only) override the global IO Capaility (set
	using the Set IO Capability command).

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	Possible values for the IO_Capability parameter:
		0	DisplayOnly
		1	DisplayYesNo
		2	KeyboardOnly
		3	NoInputNoOutput
		4	KeyboardDisplay

	Passing a value 4 (KeyboardDisplay) will cause the kernel to
	convert it to 1 (DisplayYesNo) in the case of a BR/EDR
	connection (as KeyboardDisplay is specific to SMP).

	The Address and Address_Type of the return parameters will
	return the identity address if known. In case of resolvable
	random address given as command parameters and the remote
	provides an identity resolving key, the return parameters
	will provide the resolved address.

	To allow tracking of which resolvable random address changed
	into which identity address, the New Identity Resolving Key
	event will be send before receiving Command Complete event
	for this command.

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Reject status is used when requested transport is not enabled.

	Not Supported status is used if controller is not capable with
	requested transport.

	Possible errors:	Rejected
				Not Supported
				Connect Failed
				Busy
				Invalid Parameters
				Not Powered
				Invalid Index
				Already Paired


Cancel Pair Device Command
==========================

	Command Code:		0x001A
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	The Address and Address_Type parameters should match what was
	given to a preceding Pair Device command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Invalid Parameters
				Not Powered
				Invalid Index


Unpair Device Command
=====================

	Command Code:		0x001B
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Disconnect (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	Removes all keys associated with the remote device.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The Disconnect parameter tells the kernel whether to forcefully
	disconnect any existing connections to the device. It should in
	practice always be 1 except for some special GAP qualification
	test-cases where a key removal without disconnecting is needed.

	When unpairing a device its link key, long term key and if
	provided identity resolving key will be purged.

	For devices using resolvable random addresses where the identity
	resolving key was available, after this command they will now no
	longer be resolved. The device will essentially become private
	again.

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Paired
				Invalid Parameters
				Not Powered
				Invalid Index


User Confirmation Reply Command
===============================

	Command Code:		0x001C
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to respond to a User Confirmation Request
	event.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Connected
				Invalid Parameters
				Not Powered
				Invalid Index


User Confirmation Negative Reply Command
========================================

	Command Code:		0x001D
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to return a negative response to a User
	Confirmation Request event.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Connected
				Invalid Parameters
				Not Powered
				Invalid Index


User Passkey Reply Command
==========================

	Command Code:		0x001E
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Passkey (4 Octets)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to respond to a User Confirmation Passkey
	Request event.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Connected
				Invalid Parameters
				Not Powered
				Invalid Index


User Passkey Negative Reply Command
===================================

	Command Code:		0x001F
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to return a negative response to a User
	Passkey Request event.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Not Connected
				Invalid Parameters
				Not Powered
				Invalid Index


Read Local Out Of Band Data Command
===================================

	Command Code:		0x0020
	Controller Index:	<controller id>
	Command Parameters:
	Return Parameters:	Hash_192 (16 Octets)
				Randomizer_192 (16 Octets)
				Hash_256 (16 Octets, Optional)
				Randomizer_256 (16 Octets, Optional)

	This command is used to read the local Out of Band data.

	This command can only be used when the controller is powered.

	If Secure Connections support is enabled, then this command
	will return P-192 versions of hash and randomizer as well as
	P-256 versions of both.

	Values returned by this command become invalid when the controller
	is powered down. After each power-cycle it is required to call
	this command again to get updated values.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Not Supported
				Busy
				Invalid Parameters
				Not Powered
				Invalid Index


Add Remote Out Of Band Data Command
===================================

	Command Code:		0x0021
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Hash_192 (16 Octets)
				Randomizer_192 (16 Octets)
				Hash_256 (16 Octets, Optional)
				Randomizer_256 (16 Octets, Optional)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to provide Out of Band data for a remote
	device.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	Provided Out Of Band data is persistent over power down/up toggles.

	This command also accept optional P-256 versions of hash and
	randomizer. If they are not provided, then they are set to
	zero value.

	The P-256 versions of both can also be provided when the
	support for Secure Connections is not enabled. However in
	that case they will never be used.

	To only provide the P-256 versions of hash and randomizer,
	it is valid to leave both P-192 fields as zero values. If
	Secure Connections is disabled, then of course this is the
	same as not providing any data at all.

	When providing data for remote LE devices, then the Hash_192 and
	and Randomizer_192 fields are not used and shell be set to zero.

	The Hash_256 and Randomizer_256 fields can be used for LE secure
	connections Out Of Band data. If only LE secure connections data
	is provided the Hash_P192 and Randomizer_P192 fields can be set
	to zero. Currently there is no support for providing the Security
	Manager TK Value for LE legacy pairing.

	If Secure Connections Only mode has been enabled, then providing
	Hash_P192 and Randomizer_P192 is not allowed. They are required
	to be set to zero values.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Failed
				Invalid Parameters
				Not Powered
				Invalid Index


Remove Remote Out Of Band Data Command
======================================

	Command Code:		0x0022
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to remove data added using the Add Remote
	Out Of Band Data command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	When the Address parameter is 00:00:00:00:00:00, then all
	previously added data will be removed.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Invalid Parameters
				Not Powered
				Invalid Index


Start Discovery Command
=======================

	Command Code:		0x0023
	Controller Index:	<controller id>
	Command Parameters:	Address_Type (1 Octet)
	Return Parameters:	Address_Type (1 Octet)

	This command is used to start the process of discovering remote
	devices. A Device Found event will be sent for each discovered
	device.

	Possible values for the Address_Type parameter are a bit-wise or
	of the following bits:

		0	BR/EDR
		1	LE Public
		2	LE Random

	By combining these e.g. the following values are possible:

		1	BR/EDR
		6	LE (public & random)
		7	BR/EDR/LE (interleaved discovery)

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Not Powered
				Invalid Index


Stop Discovery Command
======================

	Command Code:		0x0024
	Controller Index:	<controller id>
	Command Parameters:	Address_Type (1 Octet)
	Return Parameters:	Address_Type (1 Octet)

	This command is used to stop the discovery process started using
	the Start Discovery command.

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Rejected
				Invalid Parameters
				Invalid Index


Confirm Name Command
====================

	Command Code:		0x0025
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Name_Known (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is only valid during device discovery and is
	expected for each Device Found event with the Confirm Name
	flag set.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The Name_Known parameter should be set to 0x01 if user space
	knows the name for the device and 0x00 if it doesn't. If set to
	0x00 the kernel will perform a name resolving procedure for the
	device in question.

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Failed
				Invalid Parameters
				Invalid Index


Block Device Command
====================

	Command Code:		0x0026
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to add a device to the list of devices
	which should be blocked from being connect to the local
	controller.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	For Low Energy devices, the blocking of a device take presedence
	over auto-connection actions provided by Add Device. Blocked
	devices will not be auto-connected or even reported when found
	during background scanning. If the controller is connectable
	direct advertising from blocked devices will also be ignored.

	Connections created from advertising of the controller will
	be dropped if the device is blocked.

	This command can be used when the controller is not powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Failed
				Invalid Parameters
				Invalid Index


Unblock Device Command
======================

	Command Code:		0x0027
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to remove a device from the list of blocked
	devices (where it was added to using the Block Device command).

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	When the Address parameter is 00:00:00:00:00:00, then all
	previously blocked devices will be unblocked.

	This command can be used when the controller is not powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Set Device ID Command
=====================

	Command Code:		0x0028
	Controller Index:	<controller id>
	Command Parameters:	Source (2 Octets)
				Vendor (2 Octets)
				Product (2 Octets)
				Version (2 Octets)
	Return Parameters:

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	The Source parameter selects the organization that assigned the
	Vendor parameter:

		0x0000	Disable Device ID
		0x0001	Bluetooth SIG
		0x0002	USB Implementer’s Forum

	The information are put into the EIR data. If the controller does
	not support EIR or if SSP is disabled, this command will still
	succeed. The information are stored for later use and will survive
	toggling SSP on and off.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Set Advertising Command
=======================

	Command Code:		0x0029
	Controller Index:	<controller id>
	Command Parameters:	Advertising (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to enable LE advertising on a controller
	that supports it. The allowed values for the Advertising command
	parameter are 0x00, 0x01 and 0x02. All other values will return
	Invalid Parameters.

	The value 0x00 disables advertising, the value 0x01 enables
	advertising with considering of connectable setting and the
	value 0x02 enables advertising in connectable mode.

	Using value 0x01 means that when connectable setting is disabled,
	the advertising happens with undirected non-connectable advertising
	packets and a non-resovable random address is used. If connectable
	setting is enabled, then undirected connectable advertising packets
	and the identity address or resolvable private address are used.

	LE Devices configured via Add Device command with Action 0x01
	have no effect when using Advertising value 0x01 since only the
	connectable setting is taken into account.

	To utilize undirected connectable advertising without changing the
	connectable setting, the value 0x02 can be utilized. It makes the
	device connectable via LE without the requirement for being
	connectable on BR/EDR (and/or LE).

	The value 0x02 should be the preferred mode of operation when
	implementing peripheral mode.

	Using this command will temporarily deactive any configuration
	made by the Add Advertising command. This command takes precedence.

	A pre-requisite is that LE is already enabled, otherwise this
	command will return a "rejected" response.

	This command generates a Command Complete event on success or a
	Command Status event on failure.

	Possible errors:	Busy
				Rejected
				Not Supported
				Invalid Parameters
				Invalid Index


Set BR/EDR Command
==================

	Command Code:		0x002A
	Controller Index:	<controller id>
	Command Parameters:	BR/EDR (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to enable or disable BR/EDR support
	on a dual-mode controller. The allowed values for the Advertising
	command parameter are 0x00 and 0x01. All other values will
	return Invalid Parameters.

	A pre-requisite is that LE is already enabled, otherwise
	this command will return a "rejected" response. Enabling BR/EDR
	can be done both when powered on and powered off, however
	disabling it can only be done when powered off (otherwise the
	command will again return "rejected"). Disabling BR/EDR will
	automatically disable all other BR/EDR related settings.

	This command generates a Command Complete event on success or a
	Command Status event on failure.

	Possible errors:	Busy
				Rejected
				Not Supported
				Invalid Parameters
				Invalid Index


Set Static Address Command
==========================

	Command Code:		0x002B
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
	Return Parameters:	Current_Settings (4 Octets)

	This command allows for setting the static random address. It is
	only supported on controllers with LE support. The static random
	address is suppose to be valid for the lifetime of the
	controller or at least until the next power cycle. To ensure
	such behavior, setting of the address is limited to when the
	controller is powered off.

	The special BDADDR_ANY address (00:00:00:00:00:00) can be used
	to disable the static address.

	When a controller has a public address (which is required for
	all dual-mode controllers), this address is not used. If a dual-mode
	controller is configured as Low Energy only devices (BR/EDR has
	been switched off), then the static address is used. Only when
	the controller information reports BDADDR_ANY (00:00:00:00:00:00),
	it is required to configure a static address first.

	If privacy mode is enabled and the controller is single mode
	LE only without a public address, the static random address is
	used as identity address.

	The Static Address flag from the current settings can also be used
	to determine if the configured static address is in use or not.

	This command generates a Command Complete event on success or a
	Command Status event on failure.

	Possible errors:	Rejected
				Not Supported
				Invalid Parameters
				Invalid Index


Set Scan Parameters Command
===========================

	Command Code:		0x002C
	Controller Index:	<controller id>
	Command Parameters:	Interval (2 Octets)
				Window (2 Octets)
	Return Parameters:

	This command allows for setting the Low Energy scan parameters
	used for connection establishment and passive scanning. It is
	only supported on controllers with LE support.

	This command generates a Command Complete event on success or a
	Command Status event on failure.

	Possible errors:	Rejected
				Not Supported
				Invalid Parameters
				Invalid Index


Set Secure Connections Command
==============================

	Command Code:		0x002D
	Controller Index:	<controller id>
	Command Parameters:	Secure_Connections (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to enable/disable Secure Connections
	support for a controller. The allowed values for the
	Secure_Connections command parameter are 0x00, 0x01 and 0x02.
	All other values will return Invalid Parameters.

	The value 0x00 disables Secure Connections, the value 0x01
	enables Secure Connections and the value 0x02 enables Secure
	Connections Only mode.

	This command is only available for LE capable controllers as
	well as controllers supporting the core specification version
	4.1 or greater.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	In case the controller does not support Secure Connections
	the command will fail regardless with Not Supported error.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Set Debug Keys Command
======================

	Command Code:		0x002E
	Controller Index:	<controller id>
	Command Parameters:	Debug_Keys (1 Octet)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to tell the kernel whether to accept the
	usage of debug keys or not. The allowed values for this parameter
	are 0x00, 0x01 and 0x02. All other values will return an Invalid
	Parameters response.

	With a value of 0x00 any generated debug key will be discarded
	as soon as the connection terminates.

	With a value of 0x01 generated debug keys will be kept and can
	be used for future connections. However debug keys are always
	marked as non persistent and should not be stored. This means
	a reboot or changing the value back to 0x00 will delete them.

	With a value of 0x02 generated debug keys will be kept and can
	be used for future connections. This has the same affect as
	with value 0x01. However in addition this value will also
	enter the controller mode to generate debug keys for each
	new pairing. Changing the value back to 0x01 or 0x00 will
	disable the controller mode for generating debug keys.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Set Privacy Command
===================

	Command Code:		0x002F
	Controller Index:	<controller id>
	Command Parameters:	Privacy (1 Octet)
				Identity_Resolving_Key (16 Octets)
	Return Parameters:	Current_Settings (4 Octets)

	This command is used to enable Low Energy Privacy feature using
	resolvable private addresses.

	The value 0x00 disables privacy mode, the values 0x01 and 0x02
	enable privacy mode.

	With value 0x01 the kernel will always use the privacy mode. This
	means resolvable private address is used when the controller is
	discoverable and also when pairing is initiated.

	With value 0x02 the kernel will use privacy mode with resolvable
	private address. In case the conroller is bondable and discoverable
	the identity address is used. Also when pairing is initiated, the
	connection will be established with the identity address.

	Exposing the identity address when bondable and discoverable or
	during initated pairing can be a privacy issue. For dual-mode
	controllers this can be neglected since its public address will
	be exposed over BR/EDR anyway. The benefit of exposing the
	identity address for pairing purposes is that it makes matching
	up devices with dual-mode topology during device discovery now
	possible.

	If the privacy value 0x02 is used, then also the GATT database
	should expose the Privacy Characteristic so that remote devices
	can determine if the privacy feature is in use or not.

	When the controller has a public address (mandatory for dual-mode
	controllers) it is used as identity address. In case the controller
	is single mode LE only without a public address, it is required
	to configure a static random andress first. The privacy mode can
	only be enabled when an identity address is available.

	The Identity_Resolving_Key is the local key assigned for the local
	resolvable private address.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Invalid Index


Load Identity Resolving Keys Command
====================================

	Command Code:		0x0030
	Controller Index:	<controller id>
	Command Parameters:	Key_Count (2 Octets)
				Key1 {
					Address (6 Octets)
					Address_Type (1 Octet)
					Value (16 Octets)
				}
				Key2 {  }
				...
	Return Parameters:

	This command is used to feed the kernel with currently known
	identity resolving keys. The command does not need to be called
	again upon the receiption of New Identity Resolving Key events
	since the kernel updates its list automatically.

	Possible values for the Address_Type parameter:
		0	Reserved (not in use)
		1	LE Public
		2	LE Random

	The provided Address and Address_Type are the identity of
	a device. So either its public address or static random address.

	Unresolvable random addresses and resolvable random addresses are
	not valid and will be rejected.

	This command can be used when the controller is not powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index

#ifdef __TIZEN_PATCH__
Generate Identity Resolving Key Command
=======================================

	Command Code:		0x00F6
	Controller Index:	<controller id>
	Command Parameters:
	Return Parameters:

	This command is used to generate identity resolving key for the
	local device, which will be used at the time of pairing for key
	distribution and to	generate resolvable private address for local device.

	This command generates a Command Complete event on success
	or a Command Status event on failure.

	Possible errors:	Failed
				Invalid Index

Generate Resolvable Private Address Command
=======================================

	Command Code:		0x00F5
	Controller Index:	<controller id>
	Command Parameters:
	Return Parameters:	Resolvable Private Address (6 Octets)

	This command is used to generate resolvable private address for the
	local device when LE privacy is supported and device is having its IRK.

	This command returns generated private address which is resolvable
	by remote device on success.

	This command generates a Command Complete event on success
	or a Command Status event on failure.

	Possible errors:	Failed
				Invalid Index

Set Random Address Command
==========================

	Command Code:		0x00F4
	Controller Index:	<controller id>
	Command Parameters:	Resolvable Private Address (6 Octets)
	Return Parameters:

	This command is used to set the random address to local controller.
	If local device supports LE Privacy then this command will be called to set
	its Random address while active scanning remote devices and in the case of
	advertising itself.

	This command intern calls the HCI Set Random address command from kernel
	space to set the RPA to controller.

	This command generates a Command Complete event on success
	or a Command Status event on failure.

	Possible errors:	Failed
				Invalid Index

#endif

Get Connection Information Command
==================================

	Command Code:		0x0031
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				RSSI (1 Octet)
				TX_Power (1 Octet)
				Max_TX_Power (1 Octet)

	This command is used to get connection information.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	TX_Power and Max_TX_Power can be set to 127 if values are invalid or
	unknown. A value of 127 for RSSI indicates that it is not available.

	This command generates a Command Complete event on success and
	on failure. In case of failure only Address and Address_Type fields
	are valid and values of remaining parameters are considered invalid
	and shall be ignored.

	Possible errors:	Not Connected
				Not Powered
				Invalid Parameters
				Invalid Index


Get Clock Information Command
=============================

	Command Code:		0x0032
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Local_Clock (4 Octets)
				Piconet_Clock (4 Octets)
				Accuracy (2 Octets)

	This command is used to get local and piconet clock information.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	Reserved (not in use)
		2	Reserved (not in use)

	The Accuracy can be set to 0xffff which means the value is unknown.

	If the Address is set to 00:00:00:00:00:00, then only the
	Local_Clock field has a valid value. The Piconet_Clock and
	Accuracy fields are invalid and shall be ignored.

	This command generates a Command Complete event on success and
	on failure. In case of failure only Address and Address_Type fields
	are valid and values of remaining parameters are considered invalid
	and shall be ignored.

	Possible errors:	Not Connected
				Not Powered
				Invalid Parameters
				Invalid Index


Add Device Command
==================

	Command Code:		0x0033
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Action (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to add a device to the action list. The
	action list allows scanning for devices and enables incoming
	connections from known devices.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	Possible values for the Action parameter:
		0	Background scan for device
		1	Allow incoming connection
		2	Auto-connect remote device

	With the Action 0, when the device is found, a new Device Found
	event will be send indicating this device is available. This
	action is only valid for LE Public and LE Random address types.

	With the Action 1, the device is allowed to connect. For BR/EDR
	address type this means an incoming connection. For LE Public
	and LE Random address types, a connection will be established
	to devices using directed advertising. If successful a Device
	Connected event will be send.

	With the Action 2, when the device is found, it will be connected
	and if successful a Device Connected event will be send. This
	action is only valid for LE Public and LE Random address types.

	When a device is blocked using Block Device command, then it is
	valid to add the device here, but all actions will be ignored
	until the device is unblocked.

	Devices added with Action 1 are allowed to connect even if the
	connectable setting is off. This acts as list of known trusted
	devices.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Failed
				Invalid Parameters
				Invalid Index


Remove Device Command
=====================

	Command Code:		0x0034
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
	Return Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This command is used to remove a device from the action list
	previously added by using the Add Device command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	When the Address parameter is 00:00:00:00:00:00, then all
	previously added devices will be removed.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Load Connection Parameters Command
==================================

	Command Code:		0x0035
	Controller Index:	<controller id>
	Command Parameters:	Param_Count (2 Octets)
				Param1 {
					Address (6 Octets)
					Address_Type (1 Octet)
					Min_Connection_Interval (2 Octets)
					Max_Connection_Interval (2 Octes)
					Connection_Latency (2 Octets)
					Supervision_Timeout (2 Octets)
				}
				Param2 {  }
				...
	Return Parameters:

	This command is used to load connection parameters from several
	devices into kernel. Currently this is only supported on controllers
	with Low Energy support.

	Possible values for the Address_Type parameter:
		0	Reserved (not in use)
		1	LE Public
		2	LE Random

	The provided Address and Address_Type are the identity of
	a device. So either its public address or static random address.

	The Min_Connection_Interval, Max_Connection_Interval,
	Connection_Latency and Supervision_Timeout parameters should
	be configured as described in Core 4.1 spec, Vol 2, 7.8.12.

	This command can be used when the controller is not powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index
				Not Supported


Read Unconfigured Controller Index List Command
===============================================

	Command Code:		0x0036
	Controller Index:	<non-controller>
	Command Parameters:
	Return Parameters:	Num_Controllers (2 Octets)
				Controller_Index[i] (2 Octets)

	This command returns the list of currently unconfigured controllers.
	Unconfigured controllers added after calling this command can be
	monitored using the Unconfigured Index Added event.

	An unconfigured controller can either move to a configured state
	by indicating Unconfigured Index Removed event followed by an
	Index Added event; or it can be removed from the system which
	would be indicated by the Unconfigured Index Removed event.

	Only controllers that require configuration will be listed with
	this command. A controller that is fully configured will not
	be listed even if it supports configuration changes.

	This command generates a Command Complete event on success or
	a Command Status event on failure.


Read Controller Configuration Information Command
=================================================

	Command Code:		0x0037
	Controller Index:	<controller id>
	Command Parameters:
	Return Parameters:	Manufacturer (2 Octets)
				Supported_Options (4 Octets)
				Missing_Options (4 Octets)

	This command is used to retreive the supported configuration
	options of a controller and the missing configuration options.

	The missing options are required to be configured before the
	controller is considered fully configured and ready for standard
	operation. The command is typically used right after getting the
	response to Read Unconfigured Controller Index List command or
	Unconfigured Index Added event.

	Supported_Options and Missing_Options is a bitmask with currently
	the following available bits:

		0	External configuration
		1	Bluetooth public address configuration

	It is valid to call this command on controllers that do not
	require any configuration. It is possible that a fully configured
	controller offers additional support for configuration.

	For example a controller may contain a valid Bluetooth public
	device address, but also allows to configure it from the host
	stack. In this case the general support for configurations will
	be indicated by the Controller Configuration settings. For
	controllers where no configuration options are available that
	setting option will not be present.

	When all configurations have been completed and as a result the
	Missing_Options mask would become empty, then the now ready
	controller will be announced via Index Added event.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Set External Configuration Command
==================================

	Command Code:		0x0038
	Controller Index:	<controller id>
	Command Parameters:	Configuration (1 Octet)
	Return Parameters:	Missing_Options (4 Octets)

	This command allows to change external configuration option to
	indicate that a controller is now configured or unconfigured.

	The value 0x00 sets unconfigured state and the value 0x01 sets
	configured state of the controller.

	It is not mandatory that this configuration option is provided
	by a controller. If it is provided, the configuration has to
	happen externally using user channel operation or via vendor
	specific methods.

	Setting this option and when Missing_Options returns zero, this
	means that the controller will switch to configured state and it
	can be expected that it will be announced via Index Added event.

	Wrongly configured controllers might still cause an error when
	trying to power them via Set Powered commmand.

	This command generates a Command Complete event on success or a
	Command Status event on failure.

	Possible errors:	Rejected
				Not Supported
				Invalid Parameters
				Invalid Index


Set Public Address Command
==========================

	Command Code:		0x0039
	Controller Index:	<controller id>
	Command Parameters:	Address (6 Octets)
	Return Parameters:	Missing_Options (4 Octets)

	This command allows configuration of public address. Since a vendor
	specific procedure is required, this command might not be supported
	by all controllers. Actually most likely only a handful embedded
	controllers will offer support for this command.

	When the support for Bluetooth public address configuration is
	indicated in the supported options mask, then this command
	can be used to configure the public address.

	It is only possible to configure the public address when the
	controller is powered off.

	For an unconfigured controller and when Missing_Options returns
	an empty mask, this means that a Index Added event for the now
	fully configured controller can be expected.

	For a fully configured controller, the current controller index
	will become invalid and an Unconfigured Index Removed event will
	be send. Once the address has been successfully changed an Index
	Added event will be send. There is no guarantee that the controller
	index stays the same.

	All previous configured parameters and settings are lost when
	this command succeeds. The controller has to be treated as new
	one. Use this command for a fully configured controller only when
	you really know what you are doing.

	This command generates a Command Complete event on success or a
	Command Status event on failure.

	Possible errors:	Rejected
				Not Supported
				Invalid Parameters
				Invalid Index


Start Service Discovery Command
===============================

	Command Code:		0x003a
	Controller Index:	<controller id>
	Command Parameters:	Address_Type (1 Octet)
				RSSI_Threshold (1 Octet)
				UUID_Count (1 Octet)
				UUID[i] (16 Octets)
	Return Parameters:	Address_Type (1 Octet)

	This command is used to start the process of discovering remote
	devices with a specific UUID. A Device Found event will be sent
	for each discovered device.

	Possible values for the Address_Type parameter are a bit-wise or
	of the following bits:

		0	BR/EDR
		1	LE Public
		2	LE Random

	By combining these e.g. the following values are possible:

		1	BR/EDR
		6	LE (public & random)
		7	BR/EDR/LE (interleaved discovery)

	The service discovery uses active scanning for Low Energy scanning
	and will search for UUID in both advertising data and scan response
	data.

	Found devices that have a RSSI value smaller than RSSI_Threshold
	are not reported via DeviceFound event. Setting a value of 127
	will cause all devices to be reported.

	The list of UUIDs identifies a logical OR. Only one of the UUIDs
	have to match to cause a DeviceFound event. Providing an empty
	list of UUIDs with Num_UUID set to 0 which means that DeviceFound
	events are send out for all devices above the RSSI_Threshold.

	In case RSSI_Threshold is set to 127 and UUID_Count is 0, then
	this command behaves exactly the same as Start Discovery.

	When the discovery procedure starts the Discovery event will
	notify this similar to Start Discovery.

	This command can only be used when the controller is powered.

	This command generates a Command Complete event on success
	or failure.

	Possible errors:	Busy
				Not Supported
				Invalid Parameters
				Not Powered
				Invalid Index


Read Local Out Of Band Extended Data Command
============================================

	Command Code:		0x003b
	Controller Index:	<controller id>
	Command Parameters:	Address_Type (1 Octet)
	Return Parameters:	Address_Type (1 Octet)
				EIR_Data_Length (2 Octets)
				EIR_Data (0-65535 Octets)

	This command is used to read the local Out of Band data
	information and provide them encoded as extended inquiry
	response information or advertising data.

	Possible values for the Address_Type parameter are a bit-wise or
	of the following bits:

		0	BR/EDR
		1	LE Public
		2	LE Random

	By combining these e.g. the following values are possible:

		1	BR/EDR
		6	LE (public & random)
		7	Reserved (not in use)

	For BR/EDR controller (Address_Type 1) the returned information
	will contain the following information:

		Class of Device
		Simple Pairing Hash C-192 (optional)
		Simple Pairing Randomizer R-192 (optional)
		Simple Pairing Hash C-256 (optional)
		Simple Pairing Randomizer R-256 (optional)
		Service Class UUID (optional)
		Bluetooth Local Name (optional)

	The Simple Pairing Hash C-256 and Simple Pairing Randomizer R-256
	fields are only included when secure connections has been enabled.

	The Device Address (BD_ADDR) is not included in the EIR_Data and
	needs to be taken from controller information.

	For LE controller (Address_Type 6) the returned information
	will contain the following information:

		LE Bluetooth Device Address
		LE Role
		LE Secure Connections Confirmation Value (optional)
		LE Secure Connections Random Value (optional)
		Appearance (optional)
		Local Name (optional)
		Flags

	The LE Secure Connections Confirmation Value and LE Secure Connections
	Random Value fields are only included when secure connections has been
	enabled.

	The Security Manager TK Value from the Bluetooth specification can
	not be provided by this command. The Out Of Band information here are
	for asymmetric exchanges based on Diffie-Hellman key exchange. The
	Security Manager TK Value is a symmetric random number that has to
	be acquired and agreed upon differently.

	The returned information from BR/EDR controller and LE controller
	types are not related to each other. Once they have been used
	over an Out Of Band link, a new set of information shall be
	requested.

	When Secure Connections Only mode has been enabled, then the fields
	for Simple Pairing Hash C-192 and Simple Pairing Randomizer R-192
	are not returned. Only the fields for the strong secure connections
	pairing are included.

	This command can only be used when the controller is powered.

	Values returned by this command become invalid when the controller
	is powered down. After each power-cycle it is required to call
	this command again to get updated information.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Not Supported
				Busy
				Invalid Parameters
				Not Powered
				Invalid Index


Read Extended Controller Index List Command
===========================================

	Command Code:		0x003c
	Controller Index:	<non-controller>
	Command Parameters:
	Return Parameters:	Num_Controllers (2 Octets)
				Controller_Index[i] (2 Octets)
				Controller_Type[i] (1 Octet)
				Controller_Bus[i] (1 Octet)

	This command returns the list of currently known controllers. It
	includes configured, unconfigured and alternate controllers.

	Controllers added or removed after calling this command can be
	be monitored using the Extended Index Added and Extended Index
	Removed events.

	The existing Index Added, Index Removed, Unconfigured Index Added
	and Unconfigured Index Removed are no longer sent after this command
	has been used at least once.

	Instead of calling Read Controller Index List and Read Unconfigured
	Controller Index List, this command combines all the information
	and can be used to retrieve the controller list.

	The Controller_Type parameter has these values:

		0x00	Primary Controller (BR/EDR and/or LE)
		0x01	Unconfigured Controller (BR/EDR and/or LE)
		0x02	Alternate MAC/PHY Controller (AMP)

	The 0x00 and 0x01 types indiciate a primary BR/EDR and/or LE
	controller. The difference is just if they need extra configuration
	or if they are fully configured.

	Controllers in configured state will be listed as 0x00 and controllers
	in unconfigured state will be listed as 0x01. A controller that is
	fully configured and supports configuration changes will be listed
	as 0x00.

	Alternate MAC/PHY controllers will be listed as 0x02. They do not
	support the difference between configured and unconfigured state.

	The Controller_Bus parameter has these values:

		0x00	Virtual
		0x01	USB
		0x02	PCMCIA
		0x03	UART
		0x04	RS232
		0x05	PCI
		0x06	SDIO

	Controllers marked as RAW only operation are currently not listed
	by this command.

	This command generates a Command Complete event on success or
	a Command Status event on failure.


Read Advertising Features Command
=================================

	Command Code:		0x003d
	Controller Index:	<controller id>
	Command Parameters:
	Return Parameters:	Supported_Flags (4 Octets)
				Max_Adv_Data_Len (1 Octet)
				Max_Scan_Rsp_Len (1 Octet)
				Max_Instances (1 Octet)
				Num_Instances (1 Octet)
				Instance[i] (1 Octet)

	This command is used to read the advertising features supported
	by the controller and stack.

	With the Supported_Flags field the possible values for the Flags
	field in Add Advertising command provided:

		0	Switch into Connectable mode
		1	Advertise as Discoverable
		2	Advertise as Limited Discoverable
		3	Add Flags field to Adv_Data
		4	Add TX Power field to Adv_Data
		5	Add Appearance field to Scan_Rsp
		6	Add Local Name in Scan_Rsp

	The Flags bit 0 indicates support for connectable advertising
	and for switching to connectable advertising independent of the
	connectable global setting. When this flag is not supported, then
	the global connectable setting determines if undirected connectable,
	undirected scannable or undirected non-connectable advertising is
	used. It also determines the use of non-resolvable random address
	versus identity address or resolvable private address.

	The Flags bit 1 indicates support for advertising with discoverable
	mode enabled. Users of this flag will decrease the Max_Adv_Data_Len
	by 3 octets. In this case the advertising data flags are managed
	and added in front of the provided advertising data.

	The Flags bit 2 indicates support for advertising with limited
	discoverable mode enabled. Users of this flag will decrease the
	Max_Adv_Data_Len by 3 octets. In this case the advertising data
	flags are managed and added in front of the provided advertising
	data.

	The Flags bit 3 indicates support for automatically keeping the
	Flags field of the advertising data updated. Users of this flag
	will decrease the Max_Adv_Data_Len by 3 octets and need to keep
	that in mind. The Flags field will be added in front of the
	advertising data provided by the user. Note that with Flags bit 1
	and Flags bit 2, this one will be implicitly used even if it is
	not marked as supported.

	The Flags bit 4 indicates support for automatically adding the
	TX Power value to the advertising data. Users of this flag will
	decrease the Max_Adv_Data_Len by 3 octets. The TX Power field will
	be added at the end of the user provided advertising data. If the
	controller does not support TX Power information, then this bit will
	not be set.

	The Flags bit 5 indicates support for automatically adding the
	Apperance value to the scan response data. Users of this flag
	will decrease the Max_Scan_Rsp_len by 4 octets. The Appearance
	field will be added in front of the scan response data provided
	by the user. If the appearance value is not supported, then this
	bit will not be set.

	The Flags bit 6 indicates support for automatically adding the
	Local Name value to the scan response data. This flag indicates
	an opportunistic approach for the Local Name. If enough space
	in the scan response data is available, it will be added. If the
	space is limited a short version or no name information. The
	Local Name will be added at the end of the scan response data.

	The valid range for Instance identifiers is 1-254. The value 0
	is reserved for internal use and the value 255 is reserved for
	future extensions. However the Max_Instances value for indicating
	the number of supported Instances can be also 0 if the controller
	does not support any advertising.

	The Max_Adv_Data_Len and Max_Scan_Rsp_Len provides extra
	information about the maximum length of the data fields. For
	now this will always return the value 31. Different flags
	however might decrease the actual available length in these
	data fields.

	With Num_Instances and Instance array the current occupied
	Instance identifiers can be retrieved.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Add Advertising Command
=======================

	Command Code:		0x003e
	Controller Index:	<controller id>
	Command Parameters:	Instance (1 Octet)
				Flags (4 Octets)
				Duration (2 Octets)
				Timeout (2 Octets)
				Adv_Data_Len (1 Octet)
				Scan_Rsp_len (1 Octet)
				Adv_Data (0-255 Octets)
				Scan_Rsp (0-255 Octets)
	Return Parameters:	Instance (1 Octet)

	This command is used to configure an advertising instance that
	can be used to switch a Bluetooth Low Energy controller into
	advertising mode.

	Added advertising information with this command will be ignored
	when using the Set Advertising command to enable advertising. The
	usage of Set Advertising command take precedence over this command.

	The Instance identifier is a value between 1 and the number of
	supported instances. The value 0 is reserved.

	With the Flags value the type of advertising is controlled and
	the following flags are defined:

		0	Switch into Connectable mode
		1	Advertise as Discoverable
		2	Advertise as Limited Discoverable
		3	Add Flags field to Adv_Data
		4	Add TX Power field to Adv_Data
		5	Add Appearance field to Scan_Rsp
		6	Add Local Name in Scan_Rsp

	When the connectable flag is set, then the controller will use
	undirected connectable advertising. The value of the connectable
	setting can be overwritten this way. This is useful to switch a
	controller into connectable mode only for LE operation. This is
	similar to the mode 0x02 from the Set Advertising command.

	When the connectable flag is not set, then the controller will
	use advertising based on the connectable setting. When using
	non-connectable or scannable advertising, the controller will
	be programmed with a non-resolvable random address. When the
	system is connectable, then the identity address or resolvable
	private address will be used.

	Using the connectable flag is useful for peripheral mode support
	where BR/EDR (and/or LE) is controlled by Add Device. This allows
	making the peripheral connectable without having to interfere
	with the global connectable setting.

	If Scan_Rsp_Len is zero and connectable flag is not set and
	the global connectable setting is off, then non-connectable
	advertising is used. If Scan_Rsp_Len is larger than zero and
	connectable flag is not set and the global advertising is off,
	then scannable advertising is used. This small difference is
	supported to provide less air traffic for devices implementing
	broadcaster role.

	The Duration parameter configures the length of an Instance. The
	value is in seconds and a value of 0 indicates an automatic choice
	for the Duration. If only one advertising Instance has been added,
	then the Duration value will be ignored. It only applies for the
	case where multiple Instances are configured. In that case every
	Instance will be available for the Duration time and after that
	it switches to the next one. This is a simple round-robin based
	approach.

	The Timeout parameter configures the life-time of an Instance. In
	case the value 0 is used it indicates no expiration time. If a
	timeout value is provided, then the advertising Instace will be
	automatically removed when the timeout passes. The value for the
	timeout is in seconds. Powering down a controller will invalidate
	all advertising Instances and it is not possible to add a new
	Instance with a timeout when the controller is powered down.

	When a Timeout is provided, then the Duration substracts from
	the actual Timeout value of that Instance. For example an Instance
	with Timeout of 6 and Duration of 2 will be scheduled exactly 3
	times. Other Instances have no influence on the Timeout.

	A pre-requisite is that LE is already enabled, otherwise this
	command will return a "rejected" response.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	This command generates a Command Complete event on success or a
	Command Status event on failure.

	Possible errors:	Failed
				Rejected
				Not Supported
				Invalid Parameters
				Invalid Index


Remove Advertising Command
==========================

	Command Code:		0x003f
	Controller Index:	<controller id>
	Command Parameters:	Instance (1 Octet)
	Return Parameters:	Instance (1 Octet)

	This command is used to remove an advertising instance that
	can be used to switch a Bluetooth Low Energy controller into
	advertising mode.

	When the Instance parameter is zero, then all previously added
	advertising Instances will be removed.

	This command can be used when the controller is not powered and
	all settings will be programmed once powered.

	This command generates a Command Complete event on success or
	a Command Status event on failure.

	Possible errors:	Invalid Parameters
				Invalid Index


Command Complete Event
======================

	Event Code:		0x0001
	Controller Index:	<controller id> or <non-controller>
	Event Parameters:	Command_Opcode (2 Octets)
				Status (1 Octet)
				Return_Parameters

	This event is an indication that a command has completed. The
	fixed set of parameters includes the opcode to identify the
	command that completed as well as a status value to indicate
	success or failure. The rest of the parameters are command
	specific and documented in the section for each command
	separately.


Command Status Event
====================

	Event Code:		0x0002
	Controller Index:	<controller id> or <non-controller>
	Event Parameters:	Command_Opcode (2 Octets)
				Status (1 Octet)

	The command status event is used to indicate an early status for
	a pending command. In the case that the status indicates failure
	(anything else except success status) this also means that the
	command has finished executing.


Controller Error Event
======================

	Event Code:		0x0003
	Controller Index:	<controller id>
	Event Parameters:	Error_Code (1 Octet)

	This event maps straight to the HCI Hardware Error event and is
	used to indicate something wrong with the controller hardware.


Index Added Event
=================

	Event Code:		0x0004
	Controller Index:	<controller id>
	Event Parameters:

	This event indicates that a new controller has been added to the
	system. It is usually followed by a Read Controller Information
	command.

	Once the Read Extended Controller Index List command has been
	used at least once, the Extended Index Added event will be
	send instead of this one.


Index Removed Event
===================

	Event Code:		0x0005
	Controller Index:	<controller id>
	Event Parameters:

	This event indicates that a controller has been removed from the
	system.

	Once the Read Extended Controller Index List command has been
	used at least once, the Extended Index Removed event will be
	send instead of this one.


New Settings Event
==================

	Event Code:		0x0006
	Controller Index:	<controller id>
	Event Parameters:	Current_Settings (4 Octets)

	This event indicates that one or more of the settings for a
	controller has changed.


Class Of Device Changed Event
=============================

	Event Code:		0x0007
	Controller Index:	<controller id>
	Event Parameters:	Class_Of_Device (3 Octets)

	This event indicates that the Class of Device value for the
	controller has changed. When the controller is powered off the
	Class of Device value will always be reported as zero.


Local Name Changed Event
========================

	Event Code:		0x0008
	Controller Index:	<controller id>
	Event Parameters:	Name (249 Octets)
				Short_Name (11 Octets)

	This event indicates that the local name of the controller has
	changed.


New Link Key Event
==================

	Event Code:		0x0009
	Controller Index:	<controller id>
	Event Parameters:	Store_Hint (1 Octet)
				Key {
					Address (6 Octets)
					Address_Type (1 Octet)
					Key_Type (1 Octet)
					Value (16 Octets)
					PIN_Length (1 Octet)
				}

	This event indicates that a new link key has bee generated for a
	remote device.

	The Store_Hint parameter indicates whether the host is expected
	to store the key persistently or not (e.g. this would not be set
	if the authentication requirement was "No Bonding").

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	Reserved (not in use)
		2	Reserved (not in use)

	Public and random LE addresses are not valid and will be rejected.

	Currently defined Key_Type values are:

		0x00	Combination key
		0x01	Local Unit key
		0x02	Remote Unit key
		0x03	Debug Combination key
		0x04	Unauthenticated Combination key from P-192
		0x05	Authenticated Combination key from P-192
		0x06	Changed Combination key
		0x07	Unauthenticated Combination key from P-256
		0x08	Authenticated Combination key from P-256

	Receiving this event indicates that a pairing procecure has
	been completed.


New Long Term Key Event
=======================

	Event Code:		0x000A
	Controller Index:	<controller id>
	Event Parameters:	Store_Hint (1 Octet)
				Key {
					Address (6 Octets)
					Address_Type (1 Octet)
					Key_Type (1 Octet)
					Master (1 Octet)
					Encryption Size (1 Octet)
					Enc. Diversifier (2 Octets)
					Random Number (8 Octets)
					Value (16 Octets)
				}

	This event indicates that a new long term key has been generated
	for a remote device.

	The Store_Hint parameter indicates whether the host is expected
	to store the key persistently or not (e.g. this would not be set
	if the authentication requirement was "No Bonding").

	Possible values for the Address_Type parameter:
		0	Reserved (not in use)
		1	LE Public
		2	LE Random

	The provided Address and Address_Type are the identity of
	a device. So either its public address or static random address.

	For unresolvable random addresses and resolvable random addresses
	without identity information and identity resolving key, the
	Store_Hint will be set to not store the long term key.

	Currently defined Key_Type values are:

		0x00	Unauthenticated legacy key
		0x01	Authenticated legacy key
		0x02	Unauthenticated key from P-256
		0x03	Authenticated key from P-256
		0x04	Debug key from P-256

	Receiving this event indicates that a pairing procecure has
	been completed.


Device Connected Event
======================

	Event Code:		0x000B
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Flags (4 Octets)
				EIR_Data_Length (2 Octets)
				EIR_Data (0-65535 Octets)

	This event indicates that a successful baseband connection has
	been created to the remote device.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	For devices using resolvable random addresses with a known
	identity resolving key, the Address and Address_Type will
	contain the identity information.

	It is possible that devices get connected via its resolvable
	random address and after New Identity Resolving Key event
	start using its identity.

	The following bits are defined for the Flags parameter:
		0	Reserved (not in use)
		1	Legacy Pairing
		2	Reserved (not in use)


Device Disconnected Event
=========================

	Event Code:		0x000C
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Reason (1 Octet)

	This event indicates that the baseband connection was lost to a
	remote device.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	For devices using resolvable random addresses with a known
	identity resolving key, the Address and Address_Type will
	contain the identity information.

	Possible values for the Reason parameter:
		0	Unspecified
		1	Connection timeout
		2	Connection terminated by local host
		3	Connection terminated by remote host

	Note that the local/remote distinction just determines which side
	terminated the low-level connection, regardless of the
	disconnection of the higher-level profiles.

	This can sometimes be misleading and thus must be used with care.
	For example, some hardware combinations would report a locally
	initiated disconnection even if the user turned Bluetooth off in
	the remote side.


Connect Failed Event
====================

	Event Code:		0x000D
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Status (1 Octet)

	This event indicates that a connection attempt failed to a
	remote device.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	For devices using resolvable random addresses with a known
	identity resolving key, the Address and Address_Type will
	contain the identity information.


PIN Code Request Event
======================

	Event Code:		0x000E
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Secure (1 Octet)

	This event is used to request a PIN Code reply from user space.
	The reply should either be returned using the PIN Code Reply or
	the PIN Code Negative Reply command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	Secure: 0x01  secure PIN code required
		0x00  secure PIN code not required


User Confirmation Request Event
===============================

	Event Code:		0x000F
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Confirm_Hint (1 Octet)
				Value (4 Octets)

	This event is used to request a user confirmation request from
	user space.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	If the Confirm_Hint parameter value is 0x01 this means that
	a simple "Yes/No" confirmation should be presented to the user
	instead of a full numerical confirmation (in which case the
	parameter value will be 0x00).

	User space should respond to this command either using the User
	Confirmation Reply or the User Confirmation Negative Reply
	command.


User Passkey Request Event
==========================

	Event Code:		0x0010
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This event is used to request a passkey from user space. The
	response to this event should either be the User Passkey Reply
	command or the User Passkey Negative Reply command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random


Authentication Failed Event
===========================

	Event Code:		0x0011
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Status (1 Octet)

	This event indicates that there was an authentication failure
	with a remote device.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random


Device Found Event
==================

	Event Code:		0x0012
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				RSSI (1 Octet)
				Flags (4 Octets)
				EIR_Data_Length (2 Octets)
				EIR_Data (0-65535 Octets)

	This event indicates that a device was found during device
	discovery.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The following bits are defined for the Flags parameter:
		0	Confirm name
		1	Legacy Pairing
		2	Not Connectable

	For the RSSI field a value of 127 indicates that the RSSI is
	not available. That can happen with Bluetooth 1.1 and earlier
	controllers or with bad radio conditions.

	The Confirm name flag indicates that the kernel wants to know
	whether user space knows the name for this device or not. If
	this flag is set user space should respond to it using the
	Confirm Name command.

	The Legacy Pairing flag indicates that Legacy Pairing is likely
	to occur when pairing with this device. An application could use
	this information to optimize the pairing process by locally
	pre-generating a PIN code and thereby eliminate the risk of
	local input timeout when pairing. Note that there is a risk of
	false-positives for this flag so user space should be able to
	handle getting something else as a PIN Request when pairing.

	The Not Connectable flag indicates that the device will not
	accept any connections. This can be indicated by Low Energy
	devices that are in broadcaster role.


Discovering Event
=================

	Event Code:		0x0013
	Controller Index:	<controller id>
	Event Parameters:	Address_Type (1 Octet)
				Discovering (1 Octet)

	This event indicates that the controller has started discovering
	devices. This discovering state can come and go multiple times
	between a Start Discovery and a Stop Discovery commands.

	The Start Service Discovery command will also trigger this event.

	The valid values for the Discovering parameter are 0x01
	(enabled) and 0x00 (disabled).


Device Blocked Event
====================

	Event Code:		0x0014
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This event indicates that a device has been blocked using the
	Block Device command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The event will only be sent to Management sockets other than the
	one through which the command was sent.


Device Unblocked Event
======================

	Event Code:		0x0015
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This event indicates that a device has been unblocked using the
	Unblock Device command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The event will only be sent to Management sockets other than the
	one through which the command was sent.


Device Unpaired Event
=====================

	Event Code:		0x0016
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This event indicates that a device has been unpaired (i.e. all
	its keys have been removed from the kernel) using the Unpair
	Device command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	For devices using resolvable random addresses with a known
	identity resolving key, the event paramters will contain
	the identity. After receiving this event, the device will
	become essentially private again.

	The event will only be sent to Management sockets other than the
	one through which the Unpair Device command was sent.


Passkey Notify Event
====================

	Event Code:		0x0017
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Passkey (4 Octets)
				Entered (1 Octet)

	This event is used to request passkey notification to the user.
	Unlike the other authentication events it does not need
	responding to using any Management command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The Passkey parameter indicates the passkey to be shown to the
	user whereas the Entered parameter indicates how many characters
	the user has entered on the remote side.


New Identity Resolving Key Event
================================

	Event Code:		0x0018
	Controller Index:	<controller id>
	Event Parameters:	Store_Hint (1 Octet)
				Random_Address (6 Octets)
				Key {
					Address (6 Octets)
					Address_Type (1 Octet)
					Value (16 Octets)
				}

	This event indicates that a new identity resolving key has been
	generated for a remote device.

	The Store_Hint parameter indicates whether the host is expected
	to store the key persistently or not.

	The Random_Address provides the resolvable random address that
	was resolved into an identity. A value of 00:00:00:00:00:00
	indicates that the identity resolving key was provided for
	a public address or static random address.

	Once this event has been send for a resolvable random address,
	all further events mapping this device will send out using the
	identity address information.

	This event also indicates that now the identity address should
	be used for commands instead of the resolvable random address.

	It is possible that some devices allow discovering via its
	identity address, but after pairing using resolvable private
	address only. In such a case Store_Hint will be 0x00 and the
	Random_Address will indicate 00:00:00:00:00:00. For these devices,
	the Privacy Characteristic of the remote GATT database should
	be consulted to decide if the identity resolving key must be
	stored persistently or not.

	Devices using Set Privacy command with the option 0x02 would
	be such type of device.

	Possible values for the Address_Type parameter:
		0	Reserved (not in use)
		1	LE Public
		2	LE Random

	The provided Address and Address_Type are the identity of
	a device. So either its public address or static random address.


New Signature Resolving Key Event
=================================

	Event Code:		0x0019
	Controller Index:	<controller id>
	Event Parameters:	Store_Hint (1 Octet)
				Key {
					Address (6 Octets)
					Address_Type (1 Octet)
					Type (1 Octet)
					Value (16 Octets)
				}

	This event indicates that a new signature resolving key has been
	generated for either the master or slave device.

	The Store_Hint parameter indicates whether the host is expected
	to store the key persistently or not.

	The Type parameter has the following possible values:

		0x00	Unauthenticated local CSRK
		0x01	Unauthenticated remote CSRK
		0x02	Authenticated local CSRK
		0x03	Authenticated remote CSRK

	The local keys are used for signing data to be sent to the
	remote device, whereas the remote keys are used to verify
	signatures received from the remote device.

	The local signature resolving key will be generated with each
	pairing request. Only after receiving this event with the Type
	indicating a local key is it possible to use ATT Signed Write
	procedures.

	Possible values for the Address_Type parameter:
		0	Reserved (not in use)
		1	LE Public
		2	LE Random

	The provided Address and Address_Type are the identity of
	a device. So either its public address or static random address.


Device Added Event
==================

	Event Code:		0x001a
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)
				Action (1 Octet)

	This event indicates that a device has been added using the
	Add Device command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The event will only be sent to management sockets other than the
	one through which the command was sent.


Device Removed Event
====================

	Event Code:		0x001b
	Controller Index:	<controller id>
	Event Parameters:	Address (6 Octets)
				Address_Type (1 Octet)

	This event indicates that a device has been removed using the
	Remove Device command.

	Possible values for the Address_Type parameter:
		0	BR/EDR
		1	LE Public
		2	LE Random

	The event will only be sent to management sockets other than the
	one through which the command was sent.


New Connection Parameter Event
==============================

	Event Code:		0x001c
	Controller Index:	<controller id>
	Event Parameters:	Store_Hint (1 Octet)
				Param {
					Address (6 Octets)
					Address_Type (1 Octet)
					Min_Connection_Interval (2 Octets)
					Max_Connection_Interval (2 Octes)
					Connection_Latency (2 Octets)
					Supervision_Timeout (2 Octets)
				}

	This event indicates a new set of connection parameters from
	a peripheral device.

	The Store_Hint parameter indicates whether the host is expected
	to store this information persistently or not.

	Possible values for the Address_Type parameter:
		0	Reserved (not in use)
		1	LE Public
		2	LE Random

	The Min_Connection_Interval, Max_Connection_Interval,
	Connection_Latency and Supervision_Timeout parameters are
	encoded as described in Core 4.1 spec, Vol 2, 7.7.65.3.


Unconfigured Index Added Event
==============================

	Event Code:		0x001d
	Controller Index:	<controller id>
	Event Parameters:

	This event indicates that a new unconfigured controller has been
	added to the system. It is usually followed by a Read Controller
	Configuration Information command.

	Only when a controller requires further configuration, it will
	be announced with this event. If it supports configuration, but
	does not require it, then an Index Added event will be used.

	Once the Read Extended Controller Index List command has been
	used at least once, the Extended Index Added event will be
	send instead of this one.


Unconfigured Index Removed Event
================================

	Event Code:		0x001e
	Controller Index:	<controller id>
	Event Parameters:

	This event indicates that an unconfigured controller has been
	removed from the system.

	Once the Read Extended Controller Index List command has been
	used at least once, the Extended Index Removed event will be
	send instead of this one.


New Configuration Options Event
===============================

	Event Code:		0x001f
	Controller Index:	<controller id>
	Event Parameters:	Missing_Options (4 Octets)

	This event indicates that one or more of the options for the
	controller configuration has changed.


Extended Index Added Event
==========================

	Event Code:		0x0020
	Controller Index:	<controller id>
	Event Parameters:	Controller_Type (1 Octet)
				Controller_Bus (1 Octet)

	This event indicates that a new controller index has been
	added to the system.

	This event will only be used after Read Extended Controller Index
	List has been used at least once. If it has not been used, then
	Index Added and Unconfigured Index Added are sent instead.


Extended Index Removed Event
============================

	Event Code:		0x0021
	Controller Index:	<controller id>
	Event Parameters:	Controller_Type (1 Octet)
				Controller_Bus (1 Octet)

	This event indicates that an existing controller index has been
	removed from the system.

	This event will only be used after Read Extended Controller Index
	List has been used at least once. If it has not been used, then
	Index Removed and Unconfigured Index Removed are sent instead.


Local Out Of Band Extended Data Updated Event
=============================================

	Event Code:		0x0022
	Controller Index:	<controller id>
	Event Parameters:	Address_Type (1 Octet)
				EIR_Data_Length (2 Octets)
				EIR_Data (0-65535 Octets)

	This event is used when the Read Local Out Of Band Extended Data
	command has been used and some other user requested a new set
	of local out-of-band data. This allows for the original caller
	to adjust the data.

	Possible values for the Address_Type parameter are a bit-wise or
	of the following bits:

		0	BR/EDR
		1	LE Public
		2	LE Random

	By combining these e.g. the following values are possible:

		1	BR/EDR
		6	LE (public & random)
		7	Reserved (not in use)

	The value for EIR_Data_Length and content for EIR_Data is the
	same as described in Read Local Out Of Band Extended Data command.

	When LE Privacy is used and LE Secure Connections out-of-band
	data has been requested, then this event will be emitted every
	time the Resolvable Private Address (RPA) gets changed. The new
	RPA will be included in the EIR_Data.

	The event will only be sent to management sockets other than the
	one through which the command was sent. It will additionally also
	only be sent to sockets that have used the command at least once.


Advertising Added Event
=======================

	Event Code:		0x0023
	Controller Index:	<controller id>
	Event Parameters:	Instance (1 Octet)

	This event indicates that an advertising instance has been added
	using the Add Advertising command.

	The event will only be sent to management sockets other than the
	one through which the command was sent.


Advertising Removed Event
=========================

	Event Code:		0x0024
	Controller Index:	<controller id>
	Event Parameters:	Instance (1 Octet)

	This event indicates that an advertising instance has been removed
	using the Remove Advertising command.

	The event will only be sent to management sockets other than the
	one through which the command was sent.