diff options
author | Vladimir Oltean <vladimir.oltean@nxp.com> | 2020-03-19 22:12:10 +0200 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2020-03-19 21:37:40 -0700 |
commit | ee9d0cb6c4f42f50cdc7513fd4b8534f80fcf327 (patch) | |
tree | ec289303e1e580e81307e564027a69e456ee3bcf | |
parent | 43861da75e7cb3a97231b460d1203396c2d06642 (diff) | |
download | linux-starfive-ee9d0cb6c4f42f50cdc7513fd4b8534f80fcf327.tar.gz linux-starfive-ee9d0cb6c4f42f50cdc7513fd4b8534f80fcf327.tar.bz2 linux-starfive-ee9d0cb6c4f42f50cdc7513fd4b8534f80fcf327.zip |
net: dsa: sja1105: Avoid error message for unknown PHY mode on disabled ports
When sja1105_init_mii_settings iterates over the port list, it prints
this message for disabled ports, because they don't have a valid
phy-mode:
[ 4.778702] sja1105 spi2.0: Unsupported PHY mode unknown!
Suggested-by: Andrew Lunn <andrew@lunn.ch>
Suggested-by: Vivien Didelot <vivien.didelot@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Vivien Didelot <vivien.didelot@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
-rw-r--r-- | drivers/net/dsa/sja1105/sja1105_main.c | 3 |
1 files changed, 3 insertions, 0 deletions
diff --git a/drivers/net/dsa/sja1105/sja1105_main.c b/drivers/net/dsa/sja1105/sja1105_main.c index d8123288c572..edf57ea07083 100644 --- a/drivers/net/dsa/sja1105/sja1105_main.c +++ b/drivers/net/dsa/sja1105/sja1105_main.c @@ -162,6 +162,9 @@ static int sja1105_init_mii_settings(struct sja1105_private *priv, mii = table->entries; for (i = 0; i < SJA1105_NUM_PORTS; i++) { + if (dsa_is_unused_port(priv->ds, i)) + continue; + switch (ports[i].phy_mode) { case PHY_INTERFACE_MODE_MII: mii->xmii_mode[i] = XMII_MODE_MII; |