summaryrefslogtreecommitdiff
path: root/Documentation/networking/3c509.txt
diff options
context:
space:
mode:
authorBen Hutchings <ben@decadent.org.uk>2010-01-11 15:53:45 -0800
committerDavid S. Miller <davem@davemloft.net>2010-01-11 15:53:45 -0800
commitaa4e2e171385bb77b4da8b760d26dea2aa291587 (patch)
tree5f67c0b3fadac16db3a845ad5ab507d7acb89ba3 /Documentation/networking/3c509.txt
parenteb70df13ee52dbc0f2c0ffd8ed34a8cd27440baf (diff)
downloadlinux-exynos-aa4e2e171385bb77b4da8b760d26dea2aa291587.tar.gz
linux-exynos-aa4e2e171385bb77b4da8b760d26dea2aa291587.tar.bz2
linux-exynos-aa4e2e171385bb77b4da8b760d26dea2aa291587.zip
Documentation/3c509: document ethtool support
3c509 was changed to support ethtool in 2002, making the 'xcvr' module parameter obsolete in most cases. More recently 3c509 was converted to the modern driver model and this parameter was removed. Fix the documentation to refer to ethtool rather than the module parameter. Signed-off-by: Ben Hutchings <ben@decadent.org.uk> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation/networking/3c509.txt')
-rw-r--r--Documentation/networking/3c509.txt12
1 files changed, 8 insertions, 4 deletions
diff --git a/Documentation/networking/3c509.txt b/Documentation/networking/3c509.txt
index 0643e3b7168c..3c45d5dcd63b 100644
--- a/Documentation/networking/3c509.txt
+++ b/Documentation/networking/3c509.txt
@@ -48,11 +48,11 @@ for LILO parameters for doing this:
This configures the first found 3c509 card for IRQ 10, base I/O 0x310, and
transceiver type 3 (10base2). The flag "0x3c509" must be set to avoid conflicts
with other card types when overriding the I/O address. When the driver is
-loaded as a module, only the IRQ and transceiver setting may be overridden.
-For example, setting two cards to 10base2/IRQ10 and AUI/IRQ11 is done by using
-the xcvr and irq module options:
+loaded as a module, only the IRQ may be overridden. For example,
+setting two cards to IRQ10 and IRQ11 is done by using the irq module
+option:
- options 3c509 xcvr=3,1 irq=10,11
+ options 3c509 irq=10,11
(2) Full-duplex mode
@@ -77,6 +77,8 @@ operation.
itself full-duplex capable. This is almost certainly one of two things: a full-
duplex-capable Ethernet switch (*not* a hub), or a full-duplex-capable NIC on
another system that's connected directly to the 3c509B via a crossover cable.
+
+Full-duplex mode can be enabled using 'ethtool'.
/////Extremely important caution concerning full-duplex mode/////
Understand that the 3c509B's hardware's full-duplex support is much more
@@ -113,6 +115,8 @@ This insured that merely upgrading the driver from an earlier version would
never automatically enable full-duplex mode in an existing installation;
it must always be explicitly enabled via one of these code in order to be
activated.
+
+The transceiver type can be changed using 'ethtool'.
(4a) Interpretation of error messages and common problems