summaryrefslogtreecommitdiff
path: root/arch/arm/Kconfig
diff options
context:
space:
mode:
Diffstat (limited to 'arch/arm/Kconfig')
-rw-r--r--arch/arm/Kconfig53
1 files changed, 0 insertions, 53 deletions
diff --git a/arch/arm/Kconfig b/arch/arm/Kconfig
index ad790fc25ed..2201ff3002a 100644
--- a/arch/arm/Kconfig
+++ b/arch/arm/Kconfig
@@ -1768,59 +1768,6 @@ config FORCE_MAX_ZONEORDER
This config option is actually maximum order plus one. For example,
a value of 11 means that the largest free memory block is 2^10 pages.
-config LEDS
- bool "Timer and CPU usage LEDs"
- depends on ARCH_CDB89712 || ARCH_EBSA110 || \
- ARCH_EBSA285 || ARCH_INTEGRATOR || \
- ARCH_LUBBOCK || MACH_MAINSTONE || ARCH_NETWINDER || \
- ARCH_OMAP || ARCH_P720T || ARCH_PXA_IDP || \
- ARCH_SA1100 || ARCH_SHARK || ARCH_VERSATILE || \
- ARCH_AT91 || ARCH_DAVINCI || \
- ARCH_KS8695 || MACH_RD88F5182 || ARCH_REALVIEW
- help
- If you say Y here, the LEDs on your machine will be used
- to provide useful information about your current system status.
-
- If you are compiling a kernel for a NetWinder or EBSA-285, you will
- be able to select which LEDs are active using the options below. If
- you are compiling a kernel for the EBSA-110 or the LART however, the
- red LED will simply flash regularly to indicate that the system is
- still functional. It is safe to say Y here if you have a CATS
- system, but the driver will do nothing.
-
-config LEDS_TIMER
- bool "Timer LED" if (!ARCH_CDB89712 && !ARCH_OMAP) || \
- OMAP_OSK_MISTRAL || MACH_OMAP_H2 \
- || MACH_OMAP_PERSEUS2
- depends on LEDS
- depends on !GENERIC_CLOCKEVENTS
- default y if ARCH_EBSA110
- help
- If you say Y here, one of the system LEDs (the green one on the
- NetWinder, the amber one on the EBSA285, or the red one on the LART)
- will flash regularly to indicate that the system is still
- operational. This is mainly useful to kernel hackers who are
- debugging unstable kernels.
-
- The LART uses the same LED for both Timer LED and CPU usage LED
- functions. You may choose to use both, but the Timer LED function
- will overrule the CPU usage LED.
-
-config LEDS_CPU
- bool "CPU usage LED" if (!ARCH_CDB89712 && !ARCH_EBSA110 && \
- !ARCH_OMAP) \
- || OMAP_OSK_MISTRAL || MACH_OMAP_H2 \
- || MACH_OMAP_PERSEUS2
- depends on LEDS
- help
- If you say Y here, the red LED will be used to give a good real
- time indication of CPU usage, by lighting whenever the idle task
- is not currently executing.
-
- The LART uses the same LED for both Timer LED and CPU usage LED
- functions. You may choose to use both, but the Timer LED function
- will overrule the CPU usage LED.
-
config ALIGNMENT_TRAP
bool
depends on CPU_CP15_MMU