diff options
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/hwmon/coretemp | 7 |
1 files changed, 4 insertions, 3 deletions
diff --git a/Documentation/hwmon/coretemp b/Documentation/hwmon/coretemp index fa8776ab9b1..49c0d42dde8 100644 --- a/Documentation/hwmon/coretemp +++ b/Documentation/hwmon/coretemp @@ -49,9 +49,10 @@ tempX_label - Contains string "Core X", where X is processor number. For Package temp, this will be "Physical id Y", where Y is the package number. -The TjMax temperature is set to 85 degrees C if undocumented model specific -register (UMSR) 0xee has bit 30 set. If not the TjMax is 100 degrees C as -(sometimes) documented in processor datasheet. +On CPU models which support it, TjMax is read from a model-specific register. +On other models, it is set to an arbitrary value based on weak heuristics. +If these heuristics don't work for you, you can pass the correct TjMax value +as a module parameter (tjmax). Appendix A. Known TjMax lists (TBD): Some information comes from ark.intel.com |