summaryrefslogtreecommitdiff
path: root/fs
diff options
context:
space:
mode:
authorNeilBrown <neilb@suse.de>2011-02-24 17:25:47 +1100
committerNeilBrown <neilb@suse.de>2011-02-24 17:25:47 +1100
commit93b270f76e7ef3b81001576860c2701931cdc78b (patch)
treeabaca0e4d3e86721815498fafd06295dd9cfd002 /fs
parentda9cf5050a2e3dbc3cf26a8d908482eb4485ed49 (diff)
downloadlinux-3.10-93b270f76e7ef3b81001576860c2701931cdc78b.tar.gz
linux-3.10-93b270f76e7ef3b81001576860c2701931cdc78b.tar.bz2
linux-3.10-93b270f76e7ef3b81001576860c2701931cdc78b.zip
Fix over-zealous flush_disk when changing device size.
There are two cases when we call flush_disk. In one, the device has disappeared (check_disk_change) so any data will hold becomes irrelevant. In the oter, the device has changed size (check_disk_size_change) so data we hold may be irrelevant. In both cases it makes sense to discard any 'clean' buffers, so they will be read back from the device if needed. In the former case it makes sense to discard 'dirty' buffers as there will never be anywhere safe to write the data. In the second case it *does*not* make sense to discard dirty buffers as that will lead to file system corruption when you simply enlarge the containing devices. flush_disk calls __invalidate_devices. __invalidate_device calls both invalidate_inodes and invalidate_bdev. invalidate_inodes *does* discard I_DIRTY inodes and this does lead to fs corruption. invalidate_bev *does*not* discard dirty pages, but I don't really care about that at present. So this patch adds a flag to __invalidate_device (calling it __invalidate_device2) to indicate whether dirty buffers should be killed, and this is passed to invalidate_inodes which can choose to skip dirty inodes. flusk_disk then passes true from check_disk_change and false from check_disk_size_change. dm avoids tripping over this problem by calling i_size_write directly rathher than using check_disk_size_change. md does use check_disk_size_change and so is affected. This regression was introduced by commit 608aeef17a which causes check_disk_size_change to call flush_disk, so it is suitable for any kernel since 2.6.27. Cc: stable@kernel.org Acked-by: Jeff Moyer <jmoyer@redhat.com> Cc: Andrew Patterson <andrew.patterson@hp.com> Cc: Jens Axboe <axboe@kernel.dk> Signed-off-by: NeilBrown <neilb@suse.de>
Diffstat (limited to 'fs')
-rw-r--r--fs/block_dev.c12
-rw-r--r--fs/inode.c9
-rw-r--r--fs/internal.h2
3 files changed, 15 insertions, 8 deletions
diff --git a/fs/block_dev.c b/fs/block_dev.c
index 333a7bb4cb9..5e23152d04a 100644
--- a/fs/block_dev.c
+++ b/fs/block_dev.c
@@ -927,9 +927,9 @@ EXPORT_SYMBOL_GPL(bd_unlink_disk_holder);
* when a disk has been changed -- either by a media change or online
* resize.
*/
-static void flush_disk(struct block_device *bdev)
+static void flush_disk(struct block_device *bdev, bool kill_dirty)
{
- if (__invalidate_device(bdev)) {
+ if (__invalidate_device(bdev, kill_dirty)) {
char name[BDEVNAME_SIZE] = "";
if (bdev->bd_disk)
@@ -966,7 +966,7 @@ void check_disk_size_change(struct gendisk *disk, struct block_device *bdev)
"%s: detected capacity change from %lld to %lld\n",
name, bdev_size, disk_size);
i_size_write(bdev->bd_inode, disk_size);
- flush_disk(bdev);
+ flush_disk(bdev, false);
}
}
EXPORT_SYMBOL(check_disk_size_change);
@@ -1019,7 +1019,7 @@ int check_disk_change(struct block_device *bdev)
if (!(events & DISK_EVENT_MEDIA_CHANGE))
return 0;
- flush_disk(bdev);
+ flush_disk(bdev, true);
if (bdops->revalidate_disk)
bdops->revalidate_disk(bdev->bd_disk);
return 1;
@@ -1601,7 +1601,7 @@ fail:
}
EXPORT_SYMBOL(lookup_bdev);
-int __invalidate_device(struct block_device *bdev)
+int __invalidate_device(struct block_device *bdev, bool kill_dirty)
{
struct super_block *sb = get_super(bdev);
int res = 0;
@@ -1614,7 +1614,7 @@ int __invalidate_device(struct block_device *bdev)
* hold).
*/
shrink_dcache_sb(sb);
- res = invalidate_inodes(sb);
+ res = invalidate_inodes(sb, kill_dirty);
drop_super(sb);
}
invalidate_bdev(bdev);
diff --git a/fs/inode.c b/fs/inode.c
index da85e56378f..c50d7feb87b 100644
--- a/fs/inode.c
+++ b/fs/inode.c
@@ -540,11 +540,14 @@ void evict_inodes(struct super_block *sb)
/**
* invalidate_inodes - attempt to free all inodes on a superblock
* @sb: superblock to operate on
+ * @kill_dirty: flag to guide handling of dirty inodes
*
* Attempts to free all inodes for a given superblock. If there were any
* busy inodes return a non-zero value, else zero.
+ * If @kill_dirty is set, discard dirty inodes too, otherwise treat
+ * them as busy.
*/
-int invalidate_inodes(struct super_block *sb)
+int invalidate_inodes(struct super_block *sb, bool kill_dirty)
{
int busy = 0;
struct inode *inode, *next;
@@ -556,6 +559,10 @@ int invalidate_inodes(struct super_block *sb)
list_for_each_entry_safe(inode, next, &sb->s_inodes, i_sb_list) {
if (inode->i_state & (I_NEW | I_FREEING | I_WILL_FREE))
continue;
+ if (inode->i_state & I_DIRTY && !kill_dirty) {
+ busy = 1;
+ continue;
+ }
if (atomic_read(&inode->i_count)) {
busy = 1;
continue;
diff --git a/fs/internal.h b/fs/internal.h
index 0663568b124..9b976b57d7f 100644
--- a/fs/internal.h
+++ b/fs/internal.h
@@ -112,4 +112,4 @@ extern void release_open_intent(struct nameidata *);
*/
extern int get_nr_dirty_inodes(void);
extern void evict_inodes(struct super_block *);
-extern int invalidate_inodes(struct super_block *);
+extern int invalidate_inodes(struct super_block *, bool);