diff options
author | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-03-08 22:01:39 -0800 |
---|---|---|
committer | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-05-19 08:19:40 -0700 |
commit | 0c0a0615163e025eb978547969467012529e01d5 (patch) | |
tree | 5a30c5a7ba79426be50c8bb573fe3784badc1aa4 /Documentation/hwmon | |
parent | 84fc4585c152f34a1a90a03b7abb88a2e1218a42 (diff) | |
download | linux-3.10-0c0a0615163e025eb978547969467012529e01d5.tar.gz linux-3.10-0c0a0615163e025eb978547969467012529e01d5.tar.bz2 linux-3.10-0c0a0615163e025eb978547969467012529e01d5.zip |
hwmon: (pmbus) Support for TI UCD90xxx series Sequencer and System Health Controllers
Hardware monitoring support for TI UCD90120, UCD90124, UCD9090, and UCD90910
Sequencer and System Health Controllers.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Tom Grennan <tom.grennan@ericsson.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/ucd9000 | 110 |
1 files changed, 110 insertions, 0 deletions
diff --git a/Documentation/hwmon/ucd9000 b/Documentation/hwmon/ucd9000 new file mode 100644 index 00000000000..40ca6db50c4 --- /dev/null +++ b/Documentation/hwmon/ucd9000 @@ -0,0 +1,110 @@ +Kernel driver ucd9000 +===================== + +Supported chips: + * TI UCD90120, UCD90124, UCD9090, and UCD90910 + Prefixes: 'ucd90120', 'ucd90124', 'ucd9090', 'ucd90910' + Addresses scanned: - + Datasheets: + http://focus.ti.com/lit/ds/symlink/ucd90120.pdf + http://focus.ti.com/lit/ds/symlink/ucd90124.pdf + http://focus.ti.com/lit/ds/symlink/ucd9090.pdf + http://focus.ti.com/lit/ds/symlink/ucd90910.pdf + +Author: Guenter Roeck <guenter.roeck@ericsson.com> + + +Description +----------- + +From datasheets: + +The UCD90120 Power Supply Sequencer and System Health Monitor monitors and +sequences up to 12 independent voltage rails. The device integrates a 12-bit +ADC with a 2.5V internal reference for monitoring up to 13 power supply voltage, +current, or temperature inputs. + +The UCD90124 is a 12-rail PMBus/I2C addressable power-supply sequencer and +system-health monitor. The device integrates a 12-bit ADC for monitoring up to +13 power-supply voltage, current, or temperature inputs. Twenty-six GPIO pins +can be used for power supply enables, power-on reset signals, external +interrupts, cascading, or other system functions. Twelve of these pins offer PWM +functionality. Using these pins, the UCD90124 offers support for fan control, +margining, and general-purpose PWM functions. + +The UCD9090 is a 10-rail PMBus/I2C addressable power-supply sequencer and +monitor. The device integrates a 12-bit ADC for monitoring up to 10 power-supply +voltage inputs. Twenty-three GPIO pins can be used for power supply enables, +power-on reset signals, external interrupts, cascading, or other system +functions. Ten of these pins offer PWM functionality. Using these pins, the +UCD9090 offers support for margining, and general-purpose PWM functions. + +The UCD90910 is a ten-rail I2C / PMBus addressable power-supply sequencer and +system-health monitor. The device integrates a 12-bit ADC for monitoring up to +13 power-supply voltage, current, or temperature inputs. + +This driver is a client driver to the core PMBus driver. Please see +Documentation/hwmon/pmbus for details on PMBus client drivers. + + +Usage Notes +----------- + +This driver does not auto-detect devices. You will have to instantiate the +devices explicitly. Please see Documentation/i2c/instantiating-devices for +details. + + +Platform data support +--------------------- + +The driver supports standard PMBus driver platform data. Please see +Documentation/hwmon/pmbus for details. + + +Sysfs entries +------------- + +The following attributes are supported. Limits are read-write; all other +attributes are read-only. + +in[1-12]_label "vout[1-12]". +in[1-12]_input Measured voltage. From READ_VOUT register. +in[1-12]_min Minumum Voltage. From VOUT_UV_WARN_LIMIT register. +in[1-12]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. +in[1-12]_lcrit Critical minumum Voltage. VOUT_UV_FAULT_LIMIT register. +in[1-12]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. +in[1-12]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. +in[1-12]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. +in[1-12]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. +in[1-12]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. + +curr[1-12]_label "iout[1-12]". +curr[1-12]_input Measured current. From READ_IOUT register. +curr[1-12]_max Maximum current. From IOUT_OC_WARN_LIMIT register. +curr[1-12]_lcrit Critical minumum output current. From IOUT_UC_FAULT_LIMIT + register. +curr[1-12]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. +curr[1-12]_max_alarm Current high alarm. From IOUT_OC_WARNING status. +curr[1-12]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. + + For each attribute index, either voltage or current is + reported, but not both. If voltage or current is + reported depends on the chip configuration. + +temp[1-2]_input Measured temperatures. From READ_TEMPERATURE_1 and + READ_TEMPERATURE_2 registers. +temp[1-2]_max Maximum temperature. From OT_WARN_LIMIT register. +temp[1-2]_crit Critical high temperature. From OT_FAULT_LIMIT register. +temp[1-2]_max_alarm Temperature high alarm. +temp[1-2]_crit_alarm Temperature critical high alarm. + +fan[1-4]_input Fan RPM. +fan[1-4]_alarm Fan alarm. +fan[1-4]_fault Fan fault. + + Fan attributes are only available on chips supporting + fan control (UCD90124, UCD90910). Attribute files are + created only for enabled fans. + Note that even though UCD90910 supports up to 10 fans, + only up to four fans are currently supported. |