diff options
author | stephen hemminger <shemminger@vyatta.com> | 2011-07-06 19:00:05 +0000 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2011-07-07 00:29:31 -0700 |
commit | 6f7d32f41e5123cb3bbe8c8ce2df912d7a1e1537 (patch) | |
tree | 7f4f0482e0410e5065ed9cd9ff1c792e0b7cea9b | |
parent | d804c6f2122ae4ffac21757c7774007e38093390 (diff) | |
download | linux-3.10-6f7d32f41e5123cb3bbe8c8ce2df912d7a1e1537.tar.gz linux-3.10-6f7d32f41e5123cb3bbe8c8ce2df912d7a1e1537.tar.bz2 linux-3.10-6f7d32f41e5123cb3bbe8c8ce2df912d7a1e1537.zip |
skge: cleanup pci id table
The PCI table was using mix of defines for device id and hard coded
hex values. This patch change it to all hex values. It also adds
comments based on the names provided in the vendor driver table.
There is NO CHANGE to the actual resulting table.
Signed-off-by: Stephen Hemminger <shemminger@vyatta.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
-rw-r--r-- | drivers/net/skge.c | 21 |
1 files changed, 10 insertions, 11 deletions
diff --git a/drivers/net/skge.c b/drivers/net/skge.c index f4be5c78ebf..4042d87a266 100644 --- a/drivers/net/skge.c +++ b/drivers/net/skge.c @@ -83,17 +83,16 @@ module_param(debug, int, 0); MODULE_PARM_DESC(debug, "Debug level (0=none,...,16=all)"); static DEFINE_PCI_DEVICE_TABLE(skge_id_table) = { - { PCI_DEVICE(PCI_VENDOR_ID_3COM, PCI_DEVICE_ID_3COM_3C940) }, - { PCI_DEVICE(PCI_VENDOR_ID_3COM, PCI_DEVICE_ID_3COM_3C940B) }, - { PCI_DEVICE(PCI_VENDOR_ID_SYSKONNECT, PCI_DEVICE_ID_SYSKONNECT_GE) }, - { PCI_DEVICE(PCI_VENDOR_ID_SYSKONNECT, PCI_DEVICE_ID_SYSKONNECT_YU) }, - { PCI_DEVICE(PCI_VENDOR_ID_DLINK, PCI_DEVICE_ID_DLINK_DGE510T) }, - { PCI_DEVICE(PCI_VENDOR_ID_DLINK, 0x4b01) }, /* DGE-530T */ - { PCI_DEVICE(PCI_VENDOR_ID_MARVELL, 0x4320) }, - { PCI_DEVICE(PCI_VENDOR_ID_MARVELL, 0x5005) }, /* Belkin */ - { PCI_DEVICE(PCI_VENDOR_ID_CNET, PCI_DEVICE_ID_CNET_GIGACARD) }, - { PCI_DEVICE(PCI_VENDOR_ID_LINKSYS, PCI_DEVICE_ID_LINKSYS_EG1064) }, - { PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, 0x0015 }, + { PCI_DEVICE(PCI_VENDOR_ID_3COM, 0x1700) }, /* 3Com 3C940 */ + { PCI_DEVICE(PCI_VENDOR_ID_3COM, 0x80EB) }, /* 3Com 3C940B */ + { PCI_DEVICE(PCI_VENDOR_ID_SYSKONNECT, 0x4320) }, /* SK-98xx V2.0 */ + { PCI_DEVICE(PCI_VENDOR_ID_DLINK, 0x4b01) }, /* D-Link DGE-530T (rev.B) */ + { PCI_DEVICE(PCI_VENDOR_ID_DLINK, 0x4c00) }, /* D-Link DGE-530T */ + { PCI_DEVICE(PCI_VENDOR_ID_MARVELL, 0x4320) }, /* Marvell Yukon 88E8001/8003/8010 */ + { PCI_DEVICE(PCI_VENDOR_ID_MARVELL, 0x5005) }, /* Belkin */ + { PCI_DEVICE(PCI_VENDOR_ID_CNET, 0x434E) }, /* CNet PowerG-2000 */ + { PCI_DEVICE(PCI_VENDOR_ID_LINKSYS, 0x1064) }, /* Linksys EG1064 v2 */ + { PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, 0x0015 }, /* Linksys EG1032 v2 */ { 0 } }; MODULE_DEVICE_TABLE(pci, skge_id_table); |