summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorEric Paris <eparis@redhat.com>2010-08-27 21:42:11 -0400
committerEric Paris <eparis@redhat.com>2010-08-27 21:42:11 -0400
commit92b4678efa8ce0de9b1e01a74e3d13c4002a4136 (patch)
tree97febbafb1798324802325c22c3693902a47323d
parentf72adfd540bacc4f6ff57a7d708b1a6c8906bdb4 (diff)
downloadlinux-3.10-92b4678efa8ce0de9b1e01a74e3d13c4002a4136.tar.gz
linux-3.10-92b4678efa8ce0de9b1e01a74e3d13c4002a4136.tar.bz2
linux-3.10-92b4678efa8ce0de9b1e01a74e3d13c4002a4136.zip
fsnotify: drop two useless bools in the fnsotify main loop
The fsnotify main loop has 2 bools which indicated if we processed the inode or vfsmount mark in that particular pass through the loop. These bool can we replaced with the inode_group and vfsmount_group variables and actually make the code a little easier to understand. Signed-off-by: Eric Paris <eparis@redhat.com>
-rw-r--r--fs/notify/fsnotify.c13
1 files changed, 5 insertions, 8 deletions
diff --git a/fs/notify/fsnotify.c b/fs/notify/fsnotify.c
index 2169aa593d5..36802420d69 100644
--- a/fs/notify/fsnotify.c
+++ b/fs/notify/fsnotify.c
@@ -225,7 +225,6 @@ int fsnotify(struct inode *to_tell, __u32 mask, void *data, int data_is,
struct fsnotify_event *event = NULL;
struct vfsmount *mnt;
int idx, ret = 0;
- bool used_inode, used_vfsmount;
/* global tests shouldn't care about events on child only the specific event */
__u32 test_mask = (mask & ~FS_EVENT_ON_CHILD);
@@ -260,7 +259,6 @@ int fsnotify(struct inode *to_tell, __u32 mask, void *data, int data_is,
}
while (inode_node || vfsmount_node) {
- used_inode = used_vfsmount = false;
inode_group = vfsmount_group = NULL;
if (inode_node) {
@@ -279,23 +277,22 @@ int fsnotify(struct inode *to_tell, __u32 mask, void *data, int data_is,
/* handle inode */
send_to_group(to_tell, NULL, inode_mark, NULL, mask, data,
data_is, cookie, file_name, &event);
- used_inode = true;
+ /* we didn't use the vfsmount_mark */
+ vfsmount_group = NULL;
} else if (vfsmount_group > inode_group) {
send_to_group(to_tell, mnt, NULL, vfsmount_mark, mask, data,
data_is, cookie, file_name, &event);
- used_vfsmount = true;
+ inode_group = NULL;
} else {
send_to_group(to_tell, mnt, inode_mark, vfsmount_mark,
mask, data, data_is, cookie, file_name,
&event);
- used_vfsmount = true;
- used_inode = true;
}
- if (used_inode)
+ if (inode_group)
inode_node = srcu_dereference(inode_node->next,
&fsnotify_mark_srcu);
- if (used_vfsmount)
+ if (vfsmount_group)
vfsmount_node = srcu_dereference(vfsmount_node->next,
&fsnotify_mark_srcu);
}