thermal: Use THERMAL_TREND_{RISING|FALLING} to indicate thermal trends
Values used previously - THERMAL_TREND_{RAISE|DROP}_FULL caused thermal
governor to use the maximal cooling state just after crossing
the first trip point. Such behavior is not acceptable since it causes
the full speed of FAN which is noisy and not really necessary.
With proposed values the fan speed limit is adjusted accordingly.
Change-Id: I9b2fd96dd74040a3a0ddf8465b316b167d5c834e
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
-rw-r--r-- | drivers/thermal/samsung/exynos_thermal_common.c | 8 |
1 files changed, 5 insertions, 3 deletions
diff --git a/drivers/thermal/samsung/exynos_thermal_common.c b/drivers/thermal/samsung/exynos_thermal_common.c index c2301da08ac..510bd9fe7af 100644 --- a/drivers/thermal/samsung/exynos_thermal_common.c +++ b/drivers/thermal/samsung/exynos_thermal_common.c @@ -272,10 +272,12 @@ static int exynos_get_trend(struct thermal_zone_device *thermal, if (ret < 0) return ret; - if (thermal->temperature >= trip_temp) - *trend = THERMAL_TREND_RAISE_FULL; + if (thermal->temperature > trip_temp) + *trend = THERMAL_TREND_RAISING; + else if (thermal->temperature < trip_temp) + *trend = THERMAL_TREND_DROPPING; else - *trend = THERMAL_TREND_DROP_FULL; + *trend = THERMAL_TREND_STABLE; return 0; } |